Problems relating to firing of chain grate stokers with bituminous coal; recommendations for eliminating spontaneous combustion call for limiting heap to 1.5 tons, with maximum height of 10 ft, and that no part should be more than 10 ft from air cooled surface; selection of bituminous coal of good steam raising qualities; solutions for eliminating caking of coals include improved chain grate design; outline of further research.
Problems relating to firing of chain grate stokers with bituminous coal; recommendations for eliminating spontaneous combustion call for limiting heap to 1.5 tons, with maximum height of 10 ft, and that no part should be more than 10 ft from air cooled surface; selection of bituminous coal of good steam raising qualities; solutions for eliminating caking of coals include improved chain grate design; outline of further research.
Firing chain-grate stokers
Colliery Guardian
Arend, A.G. (author)
Colliery Guardian ; 205
1962
2 pages
Article (Journal)
English
© Metadata Copyright Elsevier B. V. All rights reserved.
Operating instructions and care of chain grate stokers
Engineering Index Backfile | 1929
|Means of reducing grate temperatures of traveling-grate stokers
Engineering Index Backfile | 1935
|Methods of clinker disposal on furnace side walls using chain grate stokers
Engineering Index Backfile | 1926
|Modern stokers compared with pulverized-coal firing
Engineering Index Backfile | 1930
|Firing of tertiary bituminous coal on underfeed stokers
Engineering Index Backfile | 1930
|