A platform for research: civil engineering, architecture and urbanism
Tests of floors of girderless (mushroom) construction
Report on experimental determination of moments in reinforced-concrete mushroom floor system of building, occupying area of 50 m. by 100 m., with pillars spaced 5.84 and 6.15 m. apart; comparison of empirical results with values derived from theoretical formulas.
Tests of floors of girderless (mushroom) construction
Report on experimental determination of moments in reinforced-concrete mushroom floor system of building, occupying area of 50 m. by 100 m., with pillars spaced 5.84 and 6.15 m. apart; comparison of empirical results with values derived from theoretical formulas.
Tests of floors of girderless (mushroom) construction
Messungen an traegerlosen (Pilz-) Decken
Probst, E. (author)
Bauingenieur ; 12
1931
2 pages
2 Figs.
Article (Journal)
German
© Metadata Copyright Elsevier B. V. All rights reserved.
Modern girderless flat-slab floors
Engineering Index Backfile | 1921
|Warehouse with a new type of girderless floors
Engineering Index Backfile | 1911
Modern designs of reinforced-concrete girderless flat-slab floors
Engineering Index Backfile | 1924
|Girderless reinforced concrete slabs
Engineering Index Backfile | 1914
|Modern storage building with girderless floor construction at Philippopel
Engineering Index Backfile | 1925
|