Protection of concrete sewers in presence of hydrogen sulfide
Review of methods to increase resistance of concrete pipe against attack; application of acid resistant barrier on concrete surfaces; impregnation of concrete; use of special concrete mixtures; simple prevention is use of larger concrete thicknesses and limestone aggregates rather than other stones.
Protection of concrete sewers in presence of hydrogen sulfide
Review of methods to increase resistance of concrete pipe against attack; application of acid resistant barrier on concrete surfaces; impregnation of concrete; use of special concrete mixtures; simple prevention is use of larger concrete thicknesses and limestone aggregates rather than other stones.
Protection of concrete sewers in presence of hydrogen sulfide
Water Sewage Works
Pomeroy, R. (author)
Water and Sewage Works ; 107
1960
4 pages
Article (Journal)
English
© Metadata Copyright Elsevier B. V. All rights reserved.
New Findings in Hydrogen Sulfide Related Corrosion of Concrete Sewers
British Library Conference Proceedings | 2009
|Optimizing Hydrogen Sulfide Control in Sewers Using Modeling
British Library Conference Proceedings | 1996
|Engineering Index Backfile | 1903
|Concrete Pipe for Sanitary Sewers-Corrosion Protection Update
British Library Conference Proceedings | 1993
|Engineering Index Backfile | 1921