Performance of alternative CFRP retrofitting schemes used in infilled RC frames
AbstractA number of experimental studies have been reported in recent literature about the beneficial effects of infill walls on the seismic response of reinforced concrete (RC) frames. The experimental study presented in this paper mainly focuses on the behavior of bare and carbon fiber reinforced polymer (CFPR)-retrofitted infilled RC frames with different bracing configurations. Quasi-static experimental results are presented and discussed on six 1/3-scaled infilled RC frames that were retrofitted using CFRP material in various schemes. The test results showed a significant increase in the yield and ultimate strength capacities of the frames with a decrease in relative story drifts, especially in the cross-braced and the cross diamond-braced type of retrofitting schemes. The energy dissipation capacities of the retrofitted frames turned out to be more than those of the bare infilled frame, thus reducing the seismic demand imposed on the frames. The cross diamond-braced type of retrofitting scheme, which was positioned on the infill wall and outside the beam–column connection regions of RC frame, showed the best behavior among the other schemes. This scheme not only prevented brittle shear failures of the infill wall, but also prevented the transfer of additional forces to the weak and brittle beam–column connections.
Performance of alternative CFRP retrofitting schemes used in infilled RC frames
AbstractA number of experimental studies have been reported in recent literature about the beneficial effects of infill walls on the seismic response of reinforced concrete (RC) frames. The experimental study presented in this paper mainly focuses on the behavior of bare and carbon fiber reinforced polymer (CFPR)-retrofitted infilled RC frames with different bracing configurations. Quasi-static experimental results are presented and discussed on six 1/3-scaled infilled RC frames that were retrofitted using CFRP material in various schemes. The test results showed a significant increase in the yield and ultimate strength capacities of the frames with a decrease in relative story drifts, especially in the cross-braced and the cross diamond-braced type of retrofitting schemes. The energy dissipation capacities of the retrofitted frames turned out to be more than those of the bare infilled frame, thus reducing the seismic demand imposed on the frames. The cross diamond-braced type of retrofitting scheme, which was positioned on the infill wall and outside the beam–column connection regions of RC frame, showed the best behavior among the other schemes. This scheme not only prevented brittle shear failures of the infill wall, but also prevented the transfer of additional forces to the weak and brittle beam–column connections.
Performance of alternative CFRP retrofitting schemes used in infilled RC frames
Yuksel, E. (author) / Ozkaynak, H. (author) / Buyukozturk, O. (author) / Yalcin, C. (author) / Dindar, A.A. (author) / Surmeli, M. (author) / Tastan, D. (author)
Construction and Building Materials ; 24 ; 596-609
2009-09-12
14 pages
Article (Journal)
Electronic Resource
English
Performance of alternative CFRP retrofitting schemes used in infilled RC frames
British Library Online Contents | 2010
|Performance of alternative CFRP retrofitting schemes used in infilled RC frames
Online Contents | 2010
Comparison of CFRP and Alternative Seismic Retrofitting Techniques for Bare and Infilled RC Frames
Online Contents | 2011
|Comparison of CFRP and Alternative Seismic Retrofitting Techniques for Bare and Infilled RC Frames
British Library Online Contents | 2011
|Out-of-plane seismic behavior and CFRP retrofitting of RC frames infilled with brick walls
Online Contents | 2012
|