A platform for research: civil engineering, architecture and urbanism
Combined torsion and axial compression loading of concrete-filled FRP tubes
Abstract Concrete-filled fiber-reinforced polymer (FRP) tubes (CFFT) were studied under combined torsion (T) and axial compression (P). Tests were performed on 166 mm diameter CFFTs with 30 MPa unconfined concrete strength (f’ ) and a nearly cross-ply FRP tube. Three stub column samples were tested in axial compression and five samples were tested in torsion while subjected to varying levels of effective axial compressive stresses, namely zero, 0.22, 0.45, 0.65, and 0.85f’ . The study showed that the P-T interaction curve was characterized by an increasing trend of T with small-to-moderate levels of P, up to a ‘balanced’ point where concrete damage mode changes, followed by a reduction in T with P thereafter. Effective axial stresses of 0.45f’ and 0.65f’ increased maximum T by 21% and 29%, respectively, while at 0.85f’ the maximum T reduced to a value similar to pure T. The maximum increase in T occurs at the balanced point where P restrains diagonal tension crack opening but does not cause concrete shear–compression damage and sliding at cracks. Failures occurred from sudden rupture of the FRP tube near a concrete crack location at high levels of twist, with a pseudo-ductile response from partial concrete confinement and FRP non-linearity. The torque contribution of the concrete core () and FRP tube () were determined using experimental data and Classical Lamination Theory (CLT). The total torque was predominantly from (66%–76%); however, this significant concrete contribution was only enabled by the FRP tube.
Highlights First study on concrete-filled FRP tubes (CFFTs) under torsion (T) & axial compression (P). T-M strength interaction curve is developed using data at P equivalent to 0, 0.22, 0.45, 0.65 and 0.85f’c. P equivalent to 0.45–0.65 f’c increased T by 21%–29%, while at 0.85f’c, T reduced to a value equal to pure T. Tube failures occurred at high levels of twist, with a pseudo-ductile response. Torque contribution of concrete core 66%–76%; but only enabled by the FRP tube.
Combined torsion and axial compression loading of concrete-filled FRP tubes
Abstract Concrete-filled fiber-reinforced polymer (FRP) tubes (CFFT) were studied under combined torsion (T) and axial compression (P). Tests were performed on 166 mm diameter CFFTs with 30 MPa unconfined concrete strength (f’ ) and a nearly cross-ply FRP tube. Three stub column samples were tested in axial compression and five samples were tested in torsion while subjected to varying levels of effective axial compressive stresses, namely zero, 0.22, 0.45, 0.65, and 0.85f’ . The study showed that the P-T interaction curve was characterized by an increasing trend of T with small-to-moderate levels of P, up to a ‘balanced’ point where concrete damage mode changes, followed by a reduction in T with P thereafter. Effective axial stresses of 0.45f’ and 0.65f’ increased maximum T by 21% and 29%, respectively, while at 0.85f’ the maximum T reduced to a value similar to pure T. The maximum increase in T occurs at the balanced point where P restrains diagonal tension crack opening but does not cause concrete shear–compression damage and sliding at cracks. Failures occurred from sudden rupture of the FRP tube near a concrete crack location at high levels of twist, with a pseudo-ductile response from partial concrete confinement and FRP non-linearity. The torque contribution of the concrete core () and FRP tube () were determined using experimental data and Classical Lamination Theory (CLT). The total torque was predominantly from (66%–76%); however, this significant concrete contribution was only enabled by the FRP tube.
Highlights First study on concrete-filled FRP tubes (CFFTs) under torsion (T) & axial compression (P). T-M strength interaction curve is developed using data at P equivalent to 0, 0.22, 0.45, 0.65 and 0.85f’c. P equivalent to 0.45–0.65 f’c increased T by 21%–29%, while at 0.85f’c, T reduced to a value equal to pure T. Tube failures occurred at high levels of twist, with a pseudo-ductile response. Torque contribution of concrete core 66%–76%; but only enabled by the FRP tube.
Combined torsion and axial compression loading of concrete-filled FRP tubes
Onge, James St. (author) / Fam, Amir (author)
Thin-Walled Structures ; 188
2023-05-14
Article (Journal)
Electronic Resource
English
CFFT , Combined loading , Compression , Concrete , Filled , FRP , Torque , Torsion , Twist
Combined Torsion, Flexure, and Axial Compression Applied to Concrete-Filled FRP Tubes
Springer Verlag | 2021
|Behaviour of Concrete-Filled Fibre Tubes Under Axial Compression and Lateral Loading
Springer Verlag | 2020
|Concrete-Filled Square FRP Tubes under Axial Compression
British Library Conference Proceedings | 2007
|Polymer concrete-filled steel tubes under axial compression
Online Contents | 2001
|