A platform for research: civil engineering, architecture and urbanism
Optimal distance between jet fans used to extinguish metropolitan tunnel fires: A case study using fire dynamic simulator modeling
Highlights A horizontal spacing between jet fans in extra-long tunnel were simulated by FDS. The effect of the length in physical model of extra- long tunnel was investigated. Numerical results were compared in terms of velocity and temperature distribution. Numerical results have been validated by a 1:15 small- scale model tunnel.
Abstract Several disastrous tunnel fires have occurred in recent decades; safe evacuation, minimization of damage, and reliable ventilation have received a great deal of attention. Here, we use the Fire Dynamic Simulator (FDS) software to optimize jet fan spacing in an extra-long tunnel: the Zhong Liangshan tunnel of Metropolitan Line 1 in Chongqing, China. The model tunnels were 500, 550, and 600 m in length, with cross-sectional areas of 30.72 m2; the jet fans were elevated 5.60 m from the floor at different spacings (100, 150, and 200 m). A 5-MW fire burned at 200, 175, and 150 m from the tunnel entrance. We simulated five scenarios using FDS software and compared airflow velocity and temperature curves. We also briefly investigated the effect of the length of an extra-long tunnel. The numerical results revealed that the air temperature always remained well below the 60 °C that the human body can withstand during evacuation necessitated by a fire; the air velocity remained nearly constant. We built a 1:15-scale model to validate the simulation; the simulation and experimental curves were in good agreement.
Optimal distance between jet fans used to extinguish metropolitan tunnel fires: A case study using fire dynamic simulator modeling
Highlights A horizontal spacing between jet fans in extra-long tunnel were simulated by FDS. The effect of the length in physical model of extra- long tunnel was investigated. Numerical results were compared in terms of velocity and temperature distribution. Numerical results have been validated by a 1:15 small- scale model tunnel.
Abstract Several disastrous tunnel fires have occurred in recent decades; safe evacuation, minimization of damage, and reliable ventilation have received a great deal of attention. Here, we use the Fire Dynamic Simulator (FDS) software to optimize jet fan spacing in an extra-long tunnel: the Zhong Liangshan tunnel of Metropolitan Line 1 in Chongqing, China. The model tunnels were 500, 550, and 600 m in length, with cross-sectional areas of 30.72 m2; the jet fans were elevated 5.60 m from the floor at different spacings (100, 150, and 200 m). A 5-MW fire burned at 200, 175, and 150 m from the tunnel entrance. We simulated five scenarios using FDS software and compared airflow velocity and temperature curves. We also briefly investigated the effect of the length of an extra-long tunnel. The numerical results revealed that the air temperature always remained well below the 60 °C that the human body can withstand during evacuation necessitated by a fire; the air velocity remained nearly constant. We built a 1:15-scale model to validate the simulation; the simulation and experimental curves were in good agreement.
Optimal distance between jet fans used to extinguish metropolitan tunnel fires: A case study using fire dynamic simulator modeling
Weng, Miaocheng (author) / Obadi, Imad (author) / Wang, Fei (author) / Liu, Fang (author) / Liao, Chunhui (author)
2019-09-10
Article (Journal)
Electronic Resource
English
Extra-long tunnel , FDS , Jet fan , Temperature , Tunnel fire , Velocity
COPING DEVICE WITH EXTINGUISH FIRE AND WATERING AND EXTINGUISH FIRE SYSTEM USING THE SAME
European Patent Office | 2017
COPING DEVICE WITH EXTINGUISH FIRE AND WATERING AND EXTINGUISH FIRE SYSTEM USING THE SAME
European Patent Office | 2017
|Use of mobile fans during tunnel fires
Elsevier | 2020
|Cryogenic Slurry Method to Extinguish Waste Bank Fires
British Library Conference Proceedings | 1994