A platform for research: civil engineering, architecture and urbanism
Hygrothermal performance of multilayer straw walls in different climates
Highlights The temperature and relative humidity variations obtained by WUFI are in good agreement with the literature experimental findings. The excessive moisture content in straw leads to bio-deterioration, mold, and decay damage in the whole structure. The hygrothermal issues in a straw wall depend on the interior and exterior covering layers. Hygrothermal issues can be solved by adding the straw thickness, adding a vapor retarder layer, adding an unventilated air layer, and controlling the indoor conditions.
Abstract Straw is becoming a promising alternative insulation material to improve the building energy performance because of its low cost, large availability as cereal waste, its good hygrothermal properties, and its low embodied energy. The goal of this paper is to assess the hygrothermal performance of multi-layered straw walls with different boundary conditions. The study consists of evaluating five different straw-based wall assemblies, under a continental (Arkhangelsk, Russia), a tropical climate (Brasilia, Brazil), a temperate Mediterranean climate (Nice, France), and a cold desert climate Xinjiang (China). Numerical models of the heat and moisture transfer through the walls using WUFI software are developed, calibrated, and validated through experimental results from the literature. The chosen evaluation criteria are the total water content, the drying rate, the condensation risk, the mold growth, the moisture quantity, the time lag, and the decrement factor. Results show that straw walls with cement and/or wood covering can be used in tropical and temperate climates, coated straw walls with additional air layers in dry climates, while insulated straw walls are best fitted in continental climates. In the latter, the dryness rate varies between 7 and 40% with a low condensation risk of value in the range of 0–12%. It can be concluded that the straw wall’s performance strongly depends on the interior and exterior added thermal insulation layers since they affect the ability of the material to dry out.
Hygrothermal performance of multilayer straw walls in different climates
Highlights The temperature and relative humidity variations obtained by WUFI are in good agreement with the literature experimental findings. The excessive moisture content in straw leads to bio-deterioration, mold, and decay damage in the whole structure. The hygrothermal issues in a straw wall depend on the interior and exterior covering layers. Hygrothermal issues can be solved by adding the straw thickness, adding a vapor retarder layer, adding an unventilated air layer, and controlling the indoor conditions.
Abstract Straw is becoming a promising alternative insulation material to improve the building energy performance because of its low cost, large availability as cereal waste, its good hygrothermal properties, and its low embodied energy. The goal of this paper is to assess the hygrothermal performance of multi-layered straw walls with different boundary conditions. The study consists of evaluating five different straw-based wall assemblies, under a continental (Arkhangelsk, Russia), a tropical climate (Brasilia, Brazil), a temperate Mediterranean climate (Nice, France), and a cold desert climate Xinjiang (China). Numerical models of the heat and moisture transfer through the walls using WUFI software are developed, calibrated, and validated through experimental results from the literature. The chosen evaluation criteria are the total water content, the drying rate, the condensation risk, the mold growth, the moisture quantity, the time lag, and the decrement factor. Results show that straw walls with cement and/or wood covering can be used in tropical and temperate climates, coated straw walls with additional air layers in dry climates, while insulated straw walls are best fitted in continental climates. In the latter, the dryness rate varies between 7 and 40% with a low condensation risk of value in the range of 0–12%. It can be concluded that the straw wall’s performance strongly depends on the interior and exterior added thermal insulation layers since they affect the ability of the material to dry out.
Hygrothermal performance of multilayer straw walls in different climates
Tlaiji, Ghadie (author) / Pennec, Fabienne (author) / Ouldboukhitine, Salah (author) / Ibrahim, Mohamad (author) / Biwole, Pascal (author)
2022-02-14
Article (Journal)
Electronic Resource
English
Hygrothermal performance of straw bales split-insulation wall assembly in cold and humid climates
Elsevier | 2024
|Hygrothermal behaviour of straw bale walls: experimental tests and numerical analyses
BASE | 2019
|Hygrothermal behaviour of straw bale walls: experimental tests and numerical analyses
DOAJ | 2019
|