Field investigation on the removal of formaldehyde in indoor air
Abstract The development of indoor air quality models requires to take into account the indoor removal processes (or “indoor sinks”) as accurately as the indoor concentrations. Field experiments were conducted in residential rooms to assess the indoor decay rate constant and deposition velocity of formaldehyde and to investigate the nature of these removal processes. The indoor decay rate constant and deposition velocity were respectively found to 0.34 ± 0.07 h−1 and (2.53 ± 0.51) × 10−3 cm s−1, indicating a high potential of depletion and therefore a low persistence of this compound in indoor environment. Considering only the impact of indoor sinks, a short indoor half-life of 2 h for formaldehyde was assessed. This high removal of formaldehyde indoors in comparison with other volatile organic compounds and its dependence with the absolute humidity suggest that the adsorption on the indoor surfaces is not the only loss process for formaldehyde. The transfer of formaldehyde to the aqueous films present onto the indoor surfaces and on the surface of airborne particles was proposed as a possible removal pathway in real indoor conditions and discussed.
Highlights Assessment the indoor decay rate of formaldehyde in real indoor conditions. Investigations on the nature of removal processes. (or “indoor sinks”). Impact of removal processes on the overall formaldehyde concentration in indoor air.
Field investigation on the removal of formaldehyde in indoor air
Abstract The development of indoor air quality models requires to take into account the indoor removal processes (or “indoor sinks”) as accurately as the indoor concentrations. Field experiments were conducted in residential rooms to assess the indoor decay rate constant and deposition velocity of formaldehyde and to investigate the nature of these removal processes. The indoor decay rate constant and deposition velocity were respectively found to 0.34 ± 0.07 h−1 and (2.53 ± 0.51) × 10−3 cm s−1, indicating a high potential of depletion and therefore a low persistence of this compound in indoor environment. Considering only the impact of indoor sinks, a short indoor half-life of 2 h for formaldehyde was assessed. This high removal of formaldehyde indoors in comparison with other volatile organic compounds and its dependence with the absolute humidity suggest that the adsorption on the indoor surfaces is not the only loss process for formaldehyde. The transfer of formaldehyde to the aqueous films present onto the indoor surfaces and on the surface of airborne particles was proposed as a possible removal pathway in real indoor conditions and discussed.
Highlights Assessment the indoor decay rate of formaldehyde in real indoor conditions. Investigations on the nature of removal processes. (or “indoor sinks”). Impact of removal processes on the overall formaldehyde concentration in indoor air.
Field investigation on the removal of formaldehyde in indoor air
Plaisance, H. (author) / Blondel, A. (author) / Desauziers, V. (author) / Mocho, P. (author)
Building and Environment ; 70 ; 277-283
2013-08-30
7 pages
Article (Journal)
Electronic Resource
English
Field investigation on the removal of formaldehyde in indoor air
British Library Online Contents | 2013
|Field investigation on the removal of formaldehyde in indoor air
Online Contents | 2013
|Removal of Indoor Formaldehyde with Ozonization
British Library Conference Proceedings | 2004
|Removal of Indoor Formaldehyde with Nanoscale Catalytic Oxidation
British Library Online Contents | 2014
|Performance of a biological degradation method for indoor formaldehyde removal
Online Contents | 2012
|