Performance evaluation of twelve low-cost PM2.5 sensors at an ambient air monitoring site
Abstract A variety of low-cost sensors are now available on the consumer market for measuring air pollutants. The use of these low-cost sensors for ambient air monitoring applications is increasing and includes fence-line or near-source monitoring, community monitoring, emergency response, hot-spot identification, mobile monitoring, epidemiological studies, and supplemental monitoring to improve the spatial-temporal resolution of current monitoring networks. Evaluating and understanding the performance of these devices is necessary to properly interpret the results and reduce confusion when low-cost sensor measurements are not in agreement with measurements from regulatory-grade instrumentation. Systematic and comprehensive field and laboratory studies comparing low-cost sensors with regulatory-grade instrumentation are necessary to characterize sensor performance. This paper presents the results of 12 particulate matter (PM) sensors measurement of PM2.5 (particles with aerodynamic diameter less than 2.5 μm) tested under ambient conditions against a federally equivalent method (FEM) instrument at an ambient air monitoring station in Riverside, CA spanning over a 3-year period from 02/05/15 to 03/27/18. Sensors were evaluated in triplicate with a typical time duration of 8-week. Performance evaluation results found 6 of the 12 sensor triplicates with average R2 values ≥ 0.70 for PM2.5 concentrations less than 50 μg/m3. Within this subset, the Mean Absolute Error (MAE) ranged from 4.4 to 7.0 μg/m3 indicating the need for caution when interpreting data from these sensors. Additional analysis revealed that the impact of relative humidity on sensor performance varied between models with several models exhibiting increased bias error with increasing humidity. Results indicate that a number of these sensors have potential as useful tools for characterizing PM2.5 levels in ambient environments when data is interpreted and understood correctly with regard to existing ambient air quality networks. The performance evaluation results are specific for Riverside, CA under non-repeatable ambient weather conditions and particle properties with the expectation that performance evaluation testing at other locations with different particle properties and weather conditions would yield similar but non-identical results.
Highlights Low-cost sensors can be useful tools for monitoring PM2.5 in ambient environments. Performance varies between different models of low-cost sensors. Intra-model variability within a PM sensor triplicate is typically low. Bias error can be impacted by changes in local environmental conditions.
Performance evaluation of twelve low-cost PM2.5 sensors at an ambient air monitoring site
Abstract A variety of low-cost sensors are now available on the consumer market for measuring air pollutants. The use of these low-cost sensors for ambient air monitoring applications is increasing and includes fence-line or near-source monitoring, community monitoring, emergency response, hot-spot identification, mobile monitoring, epidemiological studies, and supplemental monitoring to improve the spatial-temporal resolution of current monitoring networks. Evaluating and understanding the performance of these devices is necessary to properly interpret the results and reduce confusion when low-cost sensor measurements are not in agreement with measurements from regulatory-grade instrumentation. Systematic and comprehensive field and laboratory studies comparing low-cost sensors with regulatory-grade instrumentation are necessary to characterize sensor performance. This paper presents the results of 12 particulate matter (PM) sensors measurement of PM2.5 (particles with aerodynamic diameter less than 2.5 μm) tested under ambient conditions against a federally equivalent method (FEM) instrument at an ambient air monitoring station in Riverside, CA spanning over a 3-year period from 02/05/15 to 03/27/18. Sensors were evaluated in triplicate with a typical time duration of 8-week. Performance evaluation results found 6 of the 12 sensor triplicates with average R2 values ≥ 0.70 for PM2.5 concentrations less than 50 μg/m3. Within this subset, the Mean Absolute Error (MAE) ranged from 4.4 to 7.0 μg/m3 indicating the need for caution when interpreting data from these sensors. Additional analysis revealed that the impact of relative humidity on sensor performance varied between models with several models exhibiting increased bias error with increasing humidity. Results indicate that a number of these sensors have potential as useful tools for characterizing PM2.5 levels in ambient environments when data is interpreted and understood correctly with regard to existing ambient air quality networks. The performance evaluation results are specific for Riverside, CA under non-repeatable ambient weather conditions and particle properties with the expectation that performance evaluation testing at other locations with different particle properties and weather conditions would yield similar but non-identical results.
Highlights Low-cost sensors can be useful tools for monitoring PM2.5 in ambient environments. Performance varies between different models of low-cost sensors. Intra-model variability within a PM sensor triplicate is typically low. Bias error can be impacted by changes in local environmental conditions.
Performance evaluation of twelve low-cost PM2.5 sensors at an ambient air monitoring site
Feenstra, Brandon (author) / Papapostolou, Vasileios (author) / Hasheminassab, Sina (author) / Zhang, Hang (author) / Boghossian, Berj Der (author) / Cocker, David (author) / Polidori, Andrea (author)
Atmospheric Environment ; 216
2019-09-01
Article (Journal)
Electronic Resource
English
Application of Low-Cost Sensors for Accurate Ambient Temperature Monitoring
DOAJ | 2022
|DataCite | 2021
|Structural Health Monitoring with Ambient Vibration and Photonic Sensors
British Library Conference Proceedings | 2009
|Twelve Low Cost Houses. A Case Study
British Library Conference Proceedings | 2002
|STRUCTURAL HEALTH MONITORING WITH AMBIENT VIBRATION AND PHOTONIC SENSORS
British Library Conference Proceedings | 2009
|