A platform for research: civil engineering, architecture and urbanism
Lighting control strategy for energy efficient office lighting system design
Highlights Energy efficiency of an office building lighting system in Dubai is examined. Effects of daylight and artificial lighting on the HVAC system are assessed. VELUX and DIALux tools are used for daylight and lighting simulations. Lighting control logic algorithm is developed using FX tools and discussed. Integration of lighting control and space cooling systems is presented.
Abstract Lighting is the highest consumer of electrical energy in office buildings and it is one of the areas that offer many opportunities for improving the energy efficiency thereby reducing the energy consumption. This paper presents control strategy for energy efficient office lighting system design. The energy efficiency of a typical office building lighting system in Dubai is examined in this paper. The impact of use of natural lighting and artificial lighting on the HVAC system is assessed and highlighted. Lighting control algorithm is developed with the ultimate goal of achieving energy efficiency and health aspects of occupants into consideration. It is simulated using control systems simulation software functional explorer (FX) tools and recommendations are forwarded. The proposed control algorithm can be used as a reference to other new buildings to be built in Dubai or Middle East in general.
Lighting control strategy for energy efficient office lighting system design
Highlights Energy efficiency of an office building lighting system in Dubai is examined. Effects of daylight and artificial lighting on the HVAC system are assessed. VELUX and DIALux tools are used for daylight and lighting simulations. Lighting control logic algorithm is developed using FX tools and discussed. Integration of lighting control and space cooling systems is presented.
Abstract Lighting is the highest consumer of electrical energy in office buildings and it is one of the areas that offer many opportunities for improving the energy efficiency thereby reducing the energy consumption. This paper presents control strategy for energy efficient office lighting system design. The energy efficiency of a typical office building lighting system in Dubai is examined in this paper. The impact of use of natural lighting and artificial lighting on the HVAC system is assessed and highlighted. Lighting control algorithm is developed with the ultimate goal of achieving energy efficiency and health aspects of occupants into consideration. It is simulated using control systems simulation software functional explorer (FX) tools and recommendations are forwarded. The proposed control algorithm can be used as a reference to other new buildings to be built in Dubai or Middle East in general.
Lighting control strategy for energy efficient office lighting system design
Soori, Prashant Kumar (author) / Vishwas, Moheet (author)
Energy and Buildings ; 66 ; 329-337
2013-07-12
9 pages
Article (Journal)
Electronic Resource
English
Lighting control strategy for energy efficient office lighting system design
Online Contents | 2013
|Swedish lighting design requirements for energy efficient office lighting
British Library Conference Proceedings | 1996
|Efficient Lighting Design and Office Worker Productivity
British Library Conference Proceedings | 2004
|Analysis: office lighting design
Emerald Group Publishing | 1983
Office Lighting for Lighting Education
British Library Conference Proceedings | 2003
|