A platform for research: civil engineering, architecture and urbanism
Inter-story seismic isolation for high-rise buildings
Abstract Inter-story seismic isolation has become a valuable solution for high-rise buildings to effectively separate the various parts having several functions, and thus different seismic performance requirements, with the main advantage being the interruption of the flux of energy between the upper and lower stories. The isolation layers that are introduced at various heights of the buildings may filter the inertial forces transmitted to the superstructure and improve the seismic behavior of the whole system. This paper studies a 20-floor building and several inter-story configurations where the isolation layer is located at several heights, in order to discuss the performances of each model and to assess the best location along the height of the structure. OpenSees is employed to calculate the high non-linearities of the models and to consider the interaction between the vertical loads and the horizontal forces. The various responses are discussed in terms of shear forces, accelerations and drifts, demonstrating the potentialities of inter-story isolation as a means of base isolation.
Inter-story seismic isolation for high-rise buildings
Abstract Inter-story seismic isolation has become a valuable solution for high-rise buildings to effectively separate the various parts having several functions, and thus different seismic performance requirements, with the main advantage being the interruption of the flux of energy between the upper and lower stories. The isolation layers that are introduced at various heights of the buildings may filter the inertial forces transmitted to the superstructure and improve the seismic behavior of the whole system. This paper studies a 20-floor building and several inter-story configurations where the isolation layer is located at several heights, in order to discuss the performances of each model and to assess the best location along the height of the structure. OpenSees is employed to calculate the high non-linearities of the models and to consider the interaction between the vertical loads and the horizontal forces. The various responses are discussed in terms of shear forces, accelerations and drifts, demonstrating the potentialities of inter-story isolation as a means of base isolation.
Inter-story seismic isolation for high-rise buildings
Forcellini, Davide (author) / Kalfas, Konstantinos N. (author)
Engineering Structures ; 275
2022-10-19
Article (Journal)
Electronic Resource
English
Seismic Isolation Techniques for High-Rise Buildings
British Library Conference Proceedings | 1991
|Seismic Performance of Story-Added Type Buildings Remodeled with Story Seismic Isolation Systems
DOAJ | 2022
|Applying Seismic Isolation to Buildings in Japan-Retrofitting and Middle-Story Isolation
British Library Conference Proceedings | 2008
|Story-specific demand models and seismic fragility estimates for low-rise buildings
British Library Conference Proceedings | 2010
|