A platform for research: civil engineering, architecture and urbanism
Static behavior of stud connectors in bi-direction push-off tests
AbstractHeaded stud shear connectors are commonly used to transfer longitudinal shear forces across the steel-concrete interface. In order to investigate the behavior of headed shear stud connectors, bi-direction push-off tests were conducted. Eighteen specimens, including six forward and twelve inverse push-off specimens, were tested to evaluate the failure modes, bearing capacity and load-displacement relationship of studs. An accurate numerical model was developed and validated against the experimental results, and based on which extensive parametric studies were performed to investigate the variation in concrete strength, stud yield strength, stud diameter and length-to-diameter ratio of stud on the structural performance. Based on the experimental and numerical results, new design equations of stud shear capacity and stud load-slip relationship were proposed and compared with the current code of practices GB 50017-2003, AISC, EN 1994-1-1, and relevant references. Comparing to the existing approaches, the proposed formulas have a better match with the experimental values.
HighlightsSix forward and twelve inverse push-off specimens with different stud diameter and concrete strength were tested.The static behavior of stud shear connectors in inverse push-off test was thoroughly investigated and discussed.Reasonable agreement was obtained between numerical and experimental results.Practical and precise formulas were proposed to calculate the stud shear capacity and stud load-slip relationship.
Static behavior of stud connectors in bi-direction push-off tests
AbstractHeaded stud shear connectors are commonly used to transfer longitudinal shear forces across the steel-concrete interface. In order to investigate the behavior of headed shear stud connectors, bi-direction push-off tests were conducted. Eighteen specimens, including six forward and twelve inverse push-off specimens, were tested to evaluate the failure modes, bearing capacity and load-displacement relationship of studs. An accurate numerical model was developed and validated against the experimental results, and based on which extensive parametric studies were performed to investigate the variation in concrete strength, stud yield strength, stud diameter and length-to-diameter ratio of stud on the structural performance. Based on the experimental and numerical results, new design equations of stud shear capacity and stud load-slip relationship were proposed and compared with the current code of practices GB 50017-2003, AISC, EN 1994-1-1, and relevant references. Comparing to the existing approaches, the proposed formulas have a better match with the experimental values.
HighlightsSix forward and twelve inverse push-off specimens with different stud diameter and concrete strength were tested.The static behavior of stud shear connectors in inverse push-off test was thoroughly investigated and discussed.Reasonable agreement was obtained between numerical and experimental results.Practical and precise formulas were proposed to calculate the stud shear capacity and stud load-slip relationship.
Static behavior of stud connectors in bi-direction push-off tests
Ding, Fa-xing (author) / Yin, Guo-an (author) / Wang, Hai-bo (author) / Wang, Liping (author) / Guo, Qiang (author)
Thin-Walled Structures ; 120 ; 307-318
2017-09-12
12 pages
Article (Journal)
Electronic Resource
English
Static behavior of stud connectors in bi-direction push-off tests
Elsevier | 2017
|Small-scale push-out tests on welded stud shear connectors
Engineering Index Backfile | 1967
|Static behavior of large stud shear connectors
Online Contents | 2004
|Static behavior of large stud shear connectors
Elsevier | 2004
|Static behavior of large stud shear connectors
Elsevier | 2004
|