A platform for research: civil engineering, architecture and urbanism
Numerical simulation of a night cooling strategy in an office room
Abstract Night natural ventilation systems have been receiving increased attention in recent years because of their energy saving potential and environmental protection when used in passive instead of active cooling. A novel system recently proposed for cooling the building concrete slab is studied numerically in the present work. The system relies only on night ventilation as a means for cooling down the structure of the building. It consists of a new type of suspended ceiling with a peripheral gap between it and the walls combined with the positioning of the air supply and extraction grilles between the ceiling slab and the suspended ceiling. This study focuses on the use of Computational Fluid Dynamics (CFD) to predict the airflow and thermal performance of this strategy for an office room. Ansys-Fluent is used to perform the calculations both for a reduced and a full-scale room. Transient simulations were performed for a period of 24 h and the predictions for the reduced-scale model were validated by experiments under different operating conditions. The results show that the mathematical and numerical models provide satisfactory predictions of the temperature evolution in the reduced-scale model, allowing the analysis to be extended for full scale. The predictions for the office room at full scale confirm the effectiveness of the proposed cooling technique, revealing that the air peak temperature during the day is lower, as well as the temperature of the slab and the temperature of the air in the plenum during the night.
Numerical simulation of a night cooling strategy in an office room
Abstract Night natural ventilation systems have been receiving increased attention in recent years because of their energy saving potential and environmental protection when used in passive instead of active cooling. A novel system recently proposed for cooling the building concrete slab is studied numerically in the present work. The system relies only on night ventilation as a means for cooling down the structure of the building. It consists of a new type of suspended ceiling with a peripheral gap between it and the walls combined with the positioning of the air supply and extraction grilles between the ceiling slab and the suspended ceiling. This study focuses on the use of Computational Fluid Dynamics (CFD) to predict the airflow and thermal performance of this strategy for an office room. Ansys-Fluent is used to perform the calculations both for a reduced and a full-scale room. Transient simulations were performed for a period of 24 h and the predictions for the reduced-scale model were validated by experiments under different operating conditions. The results show that the mathematical and numerical models provide satisfactory predictions of the temperature evolution in the reduced-scale model, allowing the analysis to be extended for full scale. The predictions for the office room at full scale confirm the effectiveness of the proposed cooling technique, revealing that the air peak temperature during the day is lower, as well as the temperature of the slab and the temperature of the air in the plenum during the night.
Numerical simulation of a night cooling strategy in an office room
Lança, Miguel (author) / Coelho, Pedro J. (author) / Viegas, João (author)
Energy and Buildings ; 252
2021-08-11
Article (Journal)
Electronic Resource
English
British Library Online Contents | 1996
Online Contents | 1996
British Library Conference Proceedings | 1993
|Guidance and Tools for Night and Evaporative Cooling in Office Buildings
British Library Conference Proceedings | 2001
|Summer cooling with night ventilation for office buildings in moderate climates
Online Contents | 1998
|