Full-scale model test on prevention of frost heave of L-type retaining wall
Abstract In order to investigate protection against the frost heaving of seasonal frozen soil behind precast L-type retaining walls in cold regions, test walls were installed in the campus of Kitami Institute of Technology (KIT, Hokkaido, Japan) in two sections (one incorporated countermeasures against frost heave and the other had no such countermeasures). The freezing front distribution and ground temperature within the backfill were observed and deflections of the walls were measured over three freeze-thaw seasons. Some understanding of the mechanisms of frost-heave damage was gained. Simulation was undertaken to predict the shape of the freezing front in the backfill behind the L-type walls with various cross sections. These findings were employed to propose a method for cold regions to determine the appropriate zone for replacement with backfill material not susceptible to frost. For the purpose of improving the utilization of waste recycling, a two-year field test was conducted. In this test, bags filled with granular waste (glass cullet and EPS (expanded poly-styrene) volume reductions) were used as the backfill material of retaining walls in cold regions. This experiment verified that granular waste is suitable for use as a frost-heave prevention replacement material. This research results have a certain significant in designing the retaining wall of cold regions, waste recycling and protecting the natural environment.
Highlights Frost-heave mechanism is gained by freezing front distribution and behavior of walls. The effectiveness of the replacement method and the insulation method are verified. A method for determining effective replacement zone of backfill soils is proposed. The feasibility of granular material used as replacement material is verified. Horizontal component of frost heaving force acting on vertical wall is considered.
Full-scale model test on prevention of frost heave of L-type retaining wall
Abstract In order to investigate protection against the frost heaving of seasonal frozen soil behind precast L-type retaining walls in cold regions, test walls were installed in the campus of Kitami Institute of Technology (KIT, Hokkaido, Japan) in two sections (one incorporated countermeasures against frost heave and the other had no such countermeasures). The freezing front distribution and ground temperature within the backfill were observed and deflections of the walls were measured over three freeze-thaw seasons. Some understanding of the mechanisms of frost-heave damage was gained. Simulation was undertaken to predict the shape of the freezing front in the backfill behind the L-type walls with various cross sections. These findings were employed to propose a method for cold regions to determine the appropriate zone for replacement with backfill material not susceptible to frost. For the purpose of improving the utilization of waste recycling, a two-year field test was conducted. In this test, bags filled with granular waste (glass cullet and EPS (expanded poly-styrene) volume reductions) were used as the backfill material of retaining walls in cold regions. This experiment verified that granular waste is suitable for use as a frost-heave prevention replacement material. This research results have a certain significant in designing the retaining wall of cold regions, waste recycling and protecting the natural environment.
Highlights Frost-heave mechanism is gained by freezing front distribution and behavior of walls. The effectiveness of the replacement method and the insulation method are verified. A method for determining effective replacement zone of backfill soils is proposed. The feasibility of granular material used as replacement material is verified. Horizontal component of frost heaving force acting on vertical wall is considered.
Full-scale model test on prevention of frost heave of L-type retaining wall
Rui, Dahu (author) / Deng, HongYuan (author) / Nakamura, Dai (author) / Yamashita, Satoshi (author) / Suzuki, Teruyuki (author) / Zhao, HongBo (author)
Cold Regions, Science and Technology ; 132 ; 89-104
2016-07-29
16 pages
Article (Journal)
Electronic Resource
English
EPS , expanded poly-styrene , FI , freezing index , KIT , Kitami Institute of Technology , σ<inf>x</inf> , the horizontal frost force , σ<inf>n</inf> , normal frost-heave force , σ<inf>y</inf> , vertical component , L-type retaining wall , Prevention of frost heave , Replacement method , Industrial waste recycling
Full-scale model test on prevention of frost heave of L-type retaining wall
Online Contents | 2016
|Full-scale model test on prevention of frost heave of L-type retaining wall
Online Contents | 2016
|FROST HEAVE PREVENTION SYSTEM AND FROST HEAVE PREVENTION METHOD
European Patent Office | 2022
|Full-Scale Test Studies on Prevention of Frost Damage for Retaining Wall Reinforced with Geotextile
British Library Conference Proceedings | 1996
|