A platform for research: civil engineering, architecture and urbanism
Behavior of concentrically loaded high performance concrete tied columns
Highlights ► HPC has become popular in columns of high rise buildings. ► Sudden loss of strength in concentric columns before ultimate concrete strains. ► Columns must be well confined to improve post peak and ductility. ► New equation for reduction factor for computing column capacity is proposed.
Abstract The paper presents an experimental study of behavior of high performance concrete (HPC) columns under monotonic concentric loading. The test variables include strength of concrete, amount and spacing of transverse reinforcement, configuration of ties and amount and yield strength of longitudinal reinforcement. Concentrically loaded columns of HPC are characterized by early cover spalling due to the plain of separation formed between the cover and core. The equation in codes and literature to predict the axial load capacity of columns were based on tests of normal strength concrete (NSC). Hence, use of existing code equation leads to overestimation of concentric load capacities. The failure pattern is sequenced by the buckling of longitudinal bars, yielding of lateral ties and rupture of ties. The test results indicate decrease in the spacing of lateral ties and increase in volumetric ratio of transverse steel, increases marginally the strength but largely the ductility. Also an equation is proposed such that the prediction of axial load capacity is neither overestimated nor too conservative.
Behavior of concentrically loaded high performance concrete tied columns
Highlights ► HPC has become popular in columns of high rise buildings. ► Sudden loss of strength in concentric columns before ultimate concrete strains. ► Columns must be well confined to improve post peak and ductility. ► New equation for reduction factor for computing column capacity is proposed.
Abstract The paper presents an experimental study of behavior of high performance concrete (HPC) columns under monotonic concentric loading. The test variables include strength of concrete, amount and spacing of transverse reinforcement, configuration of ties and amount and yield strength of longitudinal reinforcement. Concentrically loaded columns of HPC are characterized by early cover spalling due to the plain of separation formed between the cover and core. The equation in codes and literature to predict the axial load capacity of columns were based on tests of normal strength concrete (NSC). Hence, use of existing code equation leads to overestimation of concentric load capacities. The failure pattern is sequenced by the buckling of longitudinal bars, yielding of lateral ties and rupture of ties. The test results indicate decrease in the spacing of lateral ties and increase in volumetric ratio of transverse steel, increases marginally the strength but largely the ductility. Also an equation is proposed such that the prediction of axial load capacity is neither overestimated nor too conservative.
Behavior of concentrically loaded high performance concrete tied columns
Awati, Mahesh (author) / Khadiranaikar, R.B. (author)
Engineering Structures ; 37 ; 76-87
2011-12-24
12 pages
Article (Journal)
Electronic Resource
English
Behavior of concentrically loaded high performance concrete tied columns
Online Contents | 2012
|Simplified design of concentrically loaded reinforced concrete columns
British Library Online Contents | 2014
Viewpoint: Simplified design of concentrically loaded reinforced concrete columns
British Library Online Contents | 2014
Behavior and Design of Concentrically Loaded T-Section Steel Columns
British Library Online Contents | 2014
|