A platform for research: civil engineering, architecture and urbanism
Three-dimensional finite element analyses of functionally graded femoral prostheses with different geometrical configurations
Abstract In this work, functionally graded femoral prostheses (FGFPs) with different geometrical configurations are studied using three-dimensional finite element analysis. The FGFP consists of stainless steel–hydroxyapatite (SS 316L-HA) and titanium alloy–hydroxyapatite (Ti-HA) with various volume fraction gradient exponents n=0.0, 0.1, 0.5, and 1.0. This study is the first to consider an FGFP with a combination of different profiles and cross-sections in a non-bonded implant-bone interface. The results show that the strain energy density in the proximal metaphysis of the femur increases by more than 22% in the FGFP with different geometrical configurations, which correspond to a reduction in stress shielding and subsequently decrease bone resorption. Simultaneously, the interface stresses in the bone-implant contact region have limited variations for all combinations of profiles and cross-sections. Therefore, FGFP can be employed to introduce a new optimum design for femoral prosthesis with adjustable stiffness, which can decrease stress shielding and interface stress. This condition results in an increase in the total lifespan of the hip replacement.
Highlights Functionally graded femoral prostheses (FGFPs) are studied. Different combinations of profiles and cross-sections are investigated. The strain energy density in the proximal metaphysis of the femur increases by more than 22% in the FGFP. This corresponds to a reduction in stress shielding and decrease the bone resorption. The interface stresses in the bone–implant contact region have limited variations.
Three-dimensional finite element analyses of functionally graded femoral prostheses with different geometrical configurations
Abstract In this work, functionally graded femoral prostheses (FGFPs) with different geometrical configurations are studied using three-dimensional finite element analysis. The FGFP consists of stainless steel–hydroxyapatite (SS 316L-HA) and titanium alloy–hydroxyapatite (Ti-HA) with various volume fraction gradient exponents n=0.0, 0.1, 0.5, and 1.0. This study is the first to consider an FGFP with a combination of different profiles and cross-sections in a non-bonded implant-bone interface. The results show that the strain energy density in the proximal metaphysis of the femur increases by more than 22% in the FGFP with different geometrical configurations, which correspond to a reduction in stress shielding and subsequently decrease bone resorption. Simultaneously, the interface stresses in the bone-implant contact region have limited variations for all combinations of profiles and cross-sections. Therefore, FGFP can be employed to introduce a new optimum design for femoral prosthesis with adjustable stiffness, which can decrease stress shielding and interface stress. This condition results in an increase in the total lifespan of the hip replacement.
Highlights Functionally graded femoral prostheses (FGFPs) are studied. Different combinations of profiles and cross-sections are investigated. The strain energy density in the proximal metaphysis of the femur increases by more than 22% in the FGFP. This corresponds to a reduction in stress shielding and decrease the bone resorption. The interface stresses in the bone–implant contact region have limited variations.
Three-dimensional finite element analyses of functionally graded femoral prostheses with different geometrical configurations
Oshkour, A.A. (author) / Osman, N.A. Abu (author) / Bayat, M. (author) / Afshar, R. (author) / Berto, F. (author)
2013-12-20
11 pages
Article (Journal)
Electronic Resource
English
British Library Online Contents | 2014
|British Library Online Contents | 2014
|British Library Online Contents | 2014
|Design and Analysis of Porous Functionally Graded Femoral Prostheses with Improved Stress Shielding
DOAJ | 2020
|Finite element analysis on longitudinal and radial functionally graded femoral prosthesis
British Library Online Contents | 2013
|