Abstract Vape shops are widespread due to the popularity of electronic cigarettes (e-cigs) as an alternative to tobacco cigarettes. In this study, sixty-seven Southern California vape shops were randomly surveyed for building characteristics, ventilation, and business patterns. Based on the survey results, six representative shops were recruited for real-time measurements of indoor and outdoor fine and ultrafine particles concentrations on a busy and less busy day. Occupancy, vaping frequency, and opening and closing of doors were recorded, and shop air exchange rate was determined. Indoor CO2, relative humidity, and temperature were also recorded. In addition, simultaneous measurements were taken at increasing distances away from a vaping area to assess the mixing and spatial profiles of particle levels inside the shops. During active vaping, real-time indoor particle number concentration and gravimetric-corrected PM2.5 mass concentration across the six vape shops varied from 1.3 × 104 to 4.8 × 105 particles/cm3 and from 15.5 to 37,500 μg/m3, respectively. The spatial profiles of particle number and mass were more uniformly mixed than expected in an indoor environment. Total vaping frequency was the main predictor of particle concentrations inside the vape shops when indoor-outdoor particle mass transfer is minimal (doors closed).
Graphical abstract Display Omitted
Highlights Sixty-seven vape shops were surveyed and pollutants were measured in six of them. During vaping, PM2.5 and PNC can be 10,000 times above background in vape shops. Exhaled e-cig particles persist in the air, traveling and mixing in vape shops. PM2.5 decayed faster than PNC over distances >1.5 m from a vaping source.
Fine and ultrafine particles concentrations in vape shops
Abstract Vape shops are widespread due to the popularity of electronic cigarettes (e-cigs) as an alternative to tobacco cigarettes. In this study, sixty-seven Southern California vape shops were randomly surveyed for building characteristics, ventilation, and business patterns. Based on the survey results, six representative shops were recruited for real-time measurements of indoor and outdoor fine and ultrafine particles concentrations on a busy and less busy day. Occupancy, vaping frequency, and opening and closing of doors were recorded, and shop air exchange rate was determined. Indoor CO2, relative humidity, and temperature were also recorded. In addition, simultaneous measurements were taken at increasing distances away from a vaping area to assess the mixing and spatial profiles of particle levels inside the shops. During active vaping, real-time indoor particle number concentration and gravimetric-corrected PM2.5 mass concentration across the six vape shops varied from 1.3 × 104 to 4.8 × 105 particles/cm3 and from 15.5 to 37,500 μg/m3, respectively. The spatial profiles of particle number and mass were more uniformly mixed than expected in an indoor environment. Total vaping frequency was the main predictor of particle concentrations inside the vape shops when indoor-outdoor particle mass transfer is minimal (doors closed).
Graphical abstract Display Omitted
Highlights Sixty-seven vape shops were surveyed and pollutants were measured in six of them. During vaping, PM2.5 and PNC can be 10,000 times above background in vape shops. Exhaled e-cig particles persist in the air, traveling and mixing in vape shops. PM2.5 decayed faster than PNC over distances >1.5 m from a vaping source.
Fine and ultrafine particles concentrations in vape shops
Nguyen, Charlene (author) / Li, Liqiao (author) / Sen, Chanbopha Amy (author) / Ronquillo, Emilio (author) / Zhu, Yifang (author)
Atmospheric Environment ; 211 ; 159-169
2019-05-09
11 pages
Article (Journal)
Electronic Resource
English
Number concentrations of fine and ultrafine particles containing metals
Elsevier | 2004
|Residential infiltration of fine and ultrafine particles in Edmonton
Elsevier | 2014
|Deposition of Fine and Ultrafine Particles on Indoor Surface Materials
Online Contents | 2008
|Ultrafine, fine, and black carbon particle concentrations in California child‐care facilities
Wiley | 2018
|