A platform for research: civil engineering, architecture and urbanism
Timber-timber composite (TTC) beams subjected to hogging moment
Highlights Behaviour of TTC under hogging moment was studied by testing and analytical methods. Tensile flexural failure of slab and joist was the dominant failure mode of TTC. Column opening in the CLT slab had minor impact on the loading capacity of TTC. Size of shear connectors affected the stiffness and peak load of TTC by maximum 23%. CLT slab orientation had less than 20% effect on the peak load and stiffness of TTC.
Abstract This study aims to investigate the structural behaviour of timber-timber composite (TTC) systems subject to hogging moment. A total of thirty-one TTC and six bare timber beam-to-column subassemblies (including fourteen replicates) were fabricated and tested to failure under hogging moment. The TTC beams were fabricated by connecting a cross laminated timber (CLT) slab to the top edge of a pair of laminated veneer lumber (LVL) or glued laminated timber (GLT) beams/joists. The effect of the CLT slab thickness, width, and orientation (i.e., loaded lengthwise or crosswise), column penetration in the CLT slab, bending moment to shear force ratio (span length), degree of shear interaction between the slabs and beams (controlled by the size of the shear connectors), and type of beams (LVL or GLT) on the structural performance of the TTC subassemblies were investigated experimentally. In addition, an analytical model was adopted for composite Timoshenko beams and modified to predict the stiffness and load carrying capacity of the TTC beams under hogging moment. The width of the CLT slab and column penetration in the slab (resulting in the reduction of the slab area of up to 20%) had minor (less than 9%) influence on the stiffness and peak load. However, the CLT slab thickness (in the range of 60–100 mm) had a major (up to 48%) influence on the peak load and stiffness of the TTC beam subject to hogging moment. The size of shear connectors (degree of shear connection provided by 8–12 mm screws) and orientation of the CLT slab had a moderate (max. 18–23%) influence on the load carrying capacity and stiffness of the samples.
Timber-timber composite (TTC) beams subjected to hogging moment
Highlights Behaviour of TTC under hogging moment was studied by testing and analytical methods. Tensile flexural failure of slab and joist was the dominant failure mode of TTC. Column opening in the CLT slab had minor impact on the loading capacity of TTC. Size of shear connectors affected the stiffness and peak load of TTC by maximum 23%. CLT slab orientation had less than 20% effect on the peak load and stiffness of TTC.
Abstract This study aims to investigate the structural behaviour of timber-timber composite (TTC) systems subject to hogging moment. A total of thirty-one TTC and six bare timber beam-to-column subassemblies (including fourteen replicates) were fabricated and tested to failure under hogging moment. The TTC beams were fabricated by connecting a cross laminated timber (CLT) slab to the top edge of a pair of laminated veneer lumber (LVL) or glued laminated timber (GLT) beams/joists. The effect of the CLT slab thickness, width, and orientation (i.e., loaded lengthwise or crosswise), column penetration in the CLT slab, bending moment to shear force ratio (span length), degree of shear interaction between the slabs and beams (controlled by the size of the shear connectors), and type of beams (LVL or GLT) on the structural performance of the TTC subassemblies were investigated experimentally. In addition, an analytical model was adopted for composite Timoshenko beams and modified to predict the stiffness and load carrying capacity of the TTC beams under hogging moment. The width of the CLT slab and column penetration in the slab (resulting in the reduction of the slab area of up to 20%) had minor (less than 9%) influence on the stiffness and peak load. However, the CLT slab thickness (in the range of 60–100 mm) had a major (up to 48%) influence on the peak load and stiffness of the TTC beam subject to hogging moment. The size of shear connectors (degree of shear connection provided by 8–12 mm screws) and orientation of the CLT slab had a moderate (max. 18–23%) influence on the load carrying capacity and stiffness of the samples.
Timber-timber composite (TTC) beams subjected to hogging moment
Hammad, M.W. (author) / Valipour, H.R. (author) / Ghanbari-Ghazijahani, T. (author) / Bradford, M.A. (author)
2021-12-30
Article (Journal)
Electronic Resource
English
Timber-concrete composites (TCC) floors subjected to hogging moment
Elsevier | 2024
|Mechanical Performance of Steel-Concrete Composite Beams Subjected to a Hogging Moment
Online Contents | 2014
|