A platform for research: civil engineering, architecture and urbanism
Exposure to particulate matter and ozone of outdoor origin in Singapore
Abstract Estimates of population exposure to ambient air pollution traditionally rely on concentrations measured at central-site monitors as a surrogate for concentrations to which people are exposed. In this study of Singapore, we estimate population-averaged exposure concentrations for PM2.5, PM10, and O3 by applying a model and data that account for age and gender demographics, intraurban regional variability, and microenvironmental effects with age- and gender-stratified time-activity budgets. The study addresses exposure only to air pollutants of outdoor origin. Spatially averaged midpoint estimates of lifetime ambient exposure concentrations are 59%, 52%, and 47% of outdoor concentrations for PM2.5, PM10, and O3, respectively. Utilizing ambient data for calendar year 2007, we estimate that intraurban variability in ambient concentration results in lifetime-integrated exposure concentrations in the respective ranges of 10–14 μg m−3 for PM2.5, 14–18 μg m−3 for PM10, and 7.5–15 μg m−3 for O3. Uncertainty in estimates of the indoor proportion of outdoor pollutants, which are input to the model, results in greater variability than do intraurban differences in ambient concentrations, resulting in respective ranges of 6.6–15 μg m−3 for PM2.5, 8.1–21 μg m−3 for PM10 and 6.8–16 μg m−3 for O3. Estimates of time spent in naturally ventilated (NV) homes are in the range 10–13 h/d across the population and exposures in NV homes contribute 49%, 53%, and 56% of total exposure for PM2.5, PM10 and O3, of outdoor origin, respectively. Results illustrate the importance of accurately characterizing climate-specific indoor–outdoor pollutant relationships to better quantify human exposure to air pollutants.
Highlights Central monitors are often used to characterize personal air pollution exposures. Personal exposures are affected by building operation and time-activity budget. We apply a time-concentration exposure model to an urban population in the tropics. Exposure to outdoor PM and ozone predominantly occurs in naturally ventilated homes. PM10 and O3 exposure are more sensitive than PM2.5 to residential air conditioner use.
Exposure to particulate matter and ozone of outdoor origin in Singapore
Abstract Estimates of population exposure to ambient air pollution traditionally rely on concentrations measured at central-site monitors as a surrogate for concentrations to which people are exposed. In this study of Singapore, we estimate population-averaged exposure concentrations for PM2.5, PM10, and O3 by applying a model and data that account for age and gender demographics, intraurban regional variability, and microenvironmental effects with age- and gender-stratified time-activity budgets. The study addresses exposure only to air pollutants of outdoor origin. Spatially averaged midpoint estimates of lifetime ambient exposure concentrations are 59%, 52%, and 47% of outdoor concentrations for PM2.5, PM10, and O3, respectively. Utilizing ambient data for calendar year 2007, we estimate that intraurban variability in ambient concentration results in lifetime-integrated exposure concentrations in the respective ranges of 10–14 μg m−3 for PM2.5, 14–18 μg m−3 for PM10, and 7.5–15 μg m−3 for O3. Uncertainty in estimates of the indoor proportion of outdoor pollutants, which are input to the model, results in greater variability than do intraurban differences in ambient concentrations, resulting in respective ranges of 6.6–15 μg m−3 for PM2.5, 8.1–21 μg m−3 for PM10 and 6.8–16 μg m−3 for O3. Estimates of time spent in naturally ventilated (NV) homes are in the range 10–13 h/d across the population and exposures in NV homes contribute 49%, 53%, and 56% of total exposure for PM2.5, PM10 and O3, of outdoor origin, respectively. Results illustrate the importance of accurately characterizing climate-specific indoor–outdoor pollutant relationships to better quantify human exposure to air pollutants.
Highlights Central monitors are often used to characterize personal air pollution exposures. Personal exposures are affected by building operation and time-activity budget. We apply a time-concentration exposure model to an urban population in the tropics. Exposure to outdoor PM and ozone predominantly occurs in naturally ventilated homes. PM10 and O3 exposure are more sensitive than PM2.5 to residential air conditioner use.
Exposure to particulate matter and ozone of outdoor origin in Singapore
Gall, Elliott T. (author) / Chen, Ailu (author) / Chang, Victor Wei-Chung (author) / Nazaroff, William W (author)
Building and Environment ; 93 ; 3-13
2015-03-24
11 pages
Article (Journal)
Electronic Resource
English
Exposure to particulate matter and ozone of outdoor origin in Singapore
Online Contents | 2015
|British Library Online Contents | 2007
|