A platform for research: civil engineering, architecture and urbanism
Post-fire bond behaviour in elliptical concrete filled steel tubes: Experiment and simulation
Abstract The post-fire bond behaviour between the steel tube and core concrete in elliptical concrete filled steel tubes (ECFST) is studied in this paper. A total of 15 post-fire push-out test specimens, including 9 elliptical, 3 circular and 3 square CFSTs, were designed and tested. The testing parameters included: (a) target temperatures (T tar = 20 °C, 600 °C and 800 °C); (b) high temperature duration time (t d = 30 min, 60 min, 180 min and 300 min); (c) length of long axis of elliptical section (2a = 200 mm and 300 mm); (d) section type (elliptical, circular and square). The test results indicated that the target temperature and high temperature duration time affected the post-fire bond strength of ECFSTs significantly, and the post-fire bond strength of ECFSTs could be increased with the increasing values of the two parameters. Based on the test data, a two-linear stage bond stress versus slip constitutive model considering the influence of both the temperature and fire-exposed surface area was proposed and verified to capture the post-fire bond behaviour in ECFSTs, which could be used in the refined bond behaviour numerical analysis of ECFSTs.
Highlights Experimental study on post-fire bond behaviour of elliptical concrete-filled steel tubes (ECFSTs) A simplified bond stress-slip constitutive model for ECFSTs after exposed to fire A verified finite element analysis (FEA) model to investigate post-fire bond behaviour of ECFSTs Numerical analysis on post-fire bond haviour of ECFSTs
Post-fire bond behaviour in elliptical concrete filled steel tubes: Experiment and simulation
Abstract The post-fire bond behaviour between the steel tube and core concrete in elliptical concrete filled steel tubes (ECFST) is studied in this paper. A total of 15 post-fire push-out test specimens, including 9 elliptical, 3 circular and 3 square CFSTs, were designed and tested. The testing parameters included: (a) target temperatures (T tar = 20 °C, 600 °C and 800 °C); (b) high temperature duration time (t d = 30 min, 60 min, 180 min and 300 min); (c) length of long axis of elliptical section (2a = 200 mm and 300 mm); (d) section type (elliptical, circular and square). The test results indicated that the target temperature and high temperature duration time affected the post-fire bond strength of ECFSTs significantly, and the post-fire bond strength of ECFSTs could be increased with the increasing values of the two parameters. Based on the test data, a two-linear stage bond stress versus slip constitutive model considering the influence of both the temperature and fire-exposed surface area was proposed and verified to capture the post-fire bond behaviour in ECFSTs, which could be used in the refined bond behaviour numerical analysis of ECFSTs.
Highlights Experimental study on post-fire bond behaviour of elliptical concrete-filled steel tubes (ECFSTs) A simplified bond stress-slip constitutive model for ECFSTs after exposed to fire A verified finite element analysis (FEA) model to investigate post-fire bond behaviour of ECFSTs Numerical analysis on post-fire bond haviour of ECFSTs
Post-fire bond behaviour in elliptical concrete filled steel tubes: Experiment and simulation
Song, Tian-Yi (author) / Wang, Cheng-Hao (author) / Liu, Xia-Lu (author) / Xiang, Kai (author) / Zhou, Hongyuan (author)
2022-11-27
Article (Journal)
Electronic Resource
English
Bond behaviour of elliptical concrete-filled steel tubes after fire exposure
TIBKAT | 2020
|Fire behaviour of concrete filled elliptical steel columns
Elsevier | 2010
|Fire behaviour of concrete filled elliptical steel columns
Online Contents | 2011
|Bond behavior in concrete-filled steel tubes
Elsevier | 2015
|Bond behavior in concrete-filled steel tubes
British Library Online Contents | 2016
|