A platform for research: civil engineering, architecture and urbanism
Air source integrated heat pump simulation model for EnergyPlus
AbstractAir source integrated heat pump (ASIHP) is an air source, multi-functional space-conditioning unit with water heating function (WH), which can lead to significant energy savings by recovering condensing waste heat in the cooling season and providing dedicated or desuperheating heat pump water heating in the remaining months. This paper summarizes development of the EnergyPlus ASIHP model. It introduces the physics, sub-models, working modes, and control logic. Based on the model, building energy simulations were conducted to demonstrate greater than 50% annual energy savings, in comparison to a baseline heat pump with electric water heater, over 10 US cities, using the EnergyPlus quick-service restaurant template building. We assessed water heating energy saving potentials using ASIHP versus gas heating, and identified the climate zones where ASIHPs are promising. In addition, a grid integration strategy was investigated to reveal further energy saving and electricity cost reduction potentials, via increasing the water heating set-point temperature during off-peak hours and using larger water tanks.
Air source integrated heat pump simulation model for EnergyPlus
AbstractAir source integrated heat pump (ASIHP) is an air source, multi-functional space-conditioning unit with water heating function (WH), which can lead to significant energy savings by recovering condensing waste heat in the cooling season and providing dedicated or desuperheating heat pump water heating in the remaining months. This paper summarizes development of the EnergyPlus ASIHP model. It introduces the physics, sub-models, working modes, and control logic. Based on the model, building energy simulations were conducted to demonstrate greater than 50% annual energy savings, in comparison to a baseline heat pump with electric water heater, over 10 US cities, using the EnergyPlus quick-service restaurant template building. We assessed water heating energy saving potentials using ASIHP versus gas heating, and identified the climate zones where ASIHPs are promising. In addition, a grid integration strategy was investigated to reveal further energy saving and electricity cost reduction potentials, via increasing the water heating set-point temperature during off-peak hours and using larger water tanks.
Air source integrated heat pump simulation model for EnergyPlus
Shen, Bo (author) / New, Joshua (author) / Baxter, Van (author)
Energy and Buildings ; 156 ; 197-206
2017-09-23
10 pages
Article (Journal)
Electronic Resource
English
ASIHP , air source integrated heat pump , COP , coefficient of performance , DOE , U.S. Department of Energy , DWH , dedicated water heating , HVAC , heating, ventilating, and air-conditioning , IDF , EnergyPlus input data file , SC , space cooling , SCDWH , space cooling and water heating with desuperheating , SCWH , space cooling and water heating , SH , space heating , SHDWH , space heating and water heating with desuperheating , WH , water heating (function) , Integrated heat pump , Building energy modeling , Grid Integration
Heat Pump Water Heater Modeling in EnergyPlus
NTIS | 2012
|Verification of a VRF Heat Pump Computer Model in EnergyPlus
British Library Online Contents | 2013
|Verification of a VRF Heat Pump Computer Model in EnergyPlus
British Library Conference Proceedings | 2013
|DA-13-026 A Variable Refrigerant Flow Heat Pump Computer Model in EnergyPlus
British Library Conference Proceedings | 2013
|