A platform for research: civil engineering, architecture and urbanism
Seismic performance of discontinuous cover-plate connection for prefabricated steel plate shear wall
Abstract In this study, a discontinuous cover plate connection (DCPC) was proposed for a prefabricated steel plate shear wall with a beam-only-connected infill plate. This design is suitable for prefabricated high-rise steel structures and assumes that bolt slippage does not precede the yielding of the steel plate tension field. Three 1/3-scale specimens were designed, and the hysteretic behaviour, skeleton curves, energy dissipation capacity, ductility, and failure modes were investigated using quasi-static tests and finite element analyses. Then, the hysteretic behaviour, ductility, and energy dissipation capacity of the prefabricated steel plate shear wall were compared to those of a traditional welded steel plate shear wall through finite element analyses. The results showed that the prefabricated steel plate shear wall with a DCPC had good hysteretic behaviour, energy dissipation capacity, and ductility. Further, the bolt pre-tightening force in the connection was directly proportional to the thickness of the infill plate. The ultimate lateral bearing capacity of the prefabricated steel plate shear wall was slightly less than that of the welded steel plate shear wall. In addition, the prefabricated steel plate shear wall can be assembled rapidly and simply on-site, and it provides a good post-earthquake repairable function.
Graphical abstract Display Omitted
Highlights A infill plate connection for prefabricated steel plate shear wall is proposed. The seismic behavior is obtained by model tests and finite element analysis. The pretightening force of bolts is proportional to the thickness of infill plate The bolted connection can ensure the ability of seismic rehabilitation. The discontinuous cover-plates connection exhibited good seismic behaviour.
Seismic performance of discontinuous cover-plate connection for prefabricated steel plate shear wall
Abstract In this study, a discontinuous cover plate connection (DCPC) was proposed for a prefabricated steel plate shear wall with a beam-only-connected infill plate. This design is suitable for prefabricated high-rise steel structures and assumes that bolt slippage does not precede the yielding of the steel plate tension field. Three 1/3-scale specimens were designed, and the hysteretic behaviour, skeleton curves, energy dissipation capacity, ductility, and failure modes were investigated using quasi-static tests and finite element analyses. Then, the hysteretic behaviour, ductility, and energy dissipation capacity of the prefabricated steel plate shear wall were compared to those of a traditional welded steel plate shear wall through finite element analyses. The results showed that the prefabricated steel plate shear wall with a DCPC had good hysteretic behaviour, energy dissipation capacity, and ductility. Further, the bolt pre-tightening force in the connection was directly proportional to the thickness of the infill plate. The ultimate lateral bearing capacity of the prefabricated steel plate shear wall was slightly less than that of the welded steel plate shear wall. In addition, the prefabricated steel plate shear wall can be assembled rapidly and simply on-site, and it provides a good post-earthquake repairable function.
Graphical abstract Display Omitted
Highlights A infill plate connection for prefabricated steel plate shear wall is proposed. The seismic behavior is obtained by model tests and finite element analysis. The pretightening force of bolts is proportional to the thickness of infill plate The bolted connection can ensure the ability of seismic rehabilitation. The discontinuous cover-plates connection exhibited good seismic behaviour.
Seismic performance of discontinuous cover-plate connection for prefabricated steel plate shear wall
Zhang, Xun (author) / Zhang, Ai-lin (author) / Liu, Xuechun (author)
Journal of Constructional Steel Research ; 160 ; 374-386
2019-05-30
13 pages
Article (Journal)
Electronic Resource
English
Seismic Performance of U-Shaped Connection for Prefabricated Steel Plate Shear Wall
DOAJ | 2024
|DOAJ | 2024
|Structural Seismic Performance of Prefabricated Steel Plate Shear Wall with High Energy Dissipation
Springer Verlag | 2023
|Prefabricated steel plate shear wall system with two anti-seismic defense lines
European Patent Office | 2020
|Prefabricated combined assembly type steel plate shear wall
European Patent Office | 2021
|