A platform for research: civil engineering, architecture and urbanism
Experimental evaluation of post-tensioned bridge bent under cyclic loads and comparison to hybrid bridge bents
Highlights Post-tensioned bent with a buckling restrained brace had a hysteretic energy 5.5 times that of the post tensioned-only bent. Post-tensioned bent with stretch length anchors had a hysteretic energy 3.1 times that of the post tensioned-only bent. Post tensioned-only bent had a residual drift ratio of 0.9%. The residual drift ratio of 1.1% for bent with stretch length anchros and 2.3% for bent with buckling restrained brace .
Abstract Experimental results for a re-centering bridge bent whose concrete columns were post-tensioned with unbonded high-strength steel bars are presented. The initial post-tensioning forces to achieve column re-centering were obtained using rigid body analogy. Steel collars were provided at the top and bottom ends of the columns for confinement. The column-to-footing interface contained a polyurethane layer inside the shear key to reduce column damage. For the initial post-tensioning forces implemented in the experiment, concrete damage was observed at the bottom of the columns. The post-tensioned (PT) bars remained elastic up to the design drift ratio of 2.0% and yielded at a 5.0% drift ratio; the column longitudinal mild steel bars yielded at a drift ratio of 6.0%. The performance of the post-tensioned bridge bent without any external energy dissipators (PT-Only bent) was compared with that of two similar hybrid bridge bents reinforced with external energy dissipators: the first incorporating tension-only stretch length anchors, and the second incorporating a buckling restrained brace. The two hybrid bents displayed excellent performance compared to the PT-Only bent in terms of strength, stiffness, and hysteretic energy dissipation; however, the PT-Only bent had a superior re-centering efficiency compared to the two hybrid bents.
Experimental evaluation of post-tensioned bridge bent under cyclic loads and comparison to hybrid bridge bents
Highlights Post-tensioned bent with a buckling restrained brace had a hysteretic energy 5.5 times that of the post tensioned-only bent. Post-tensioned bent with stretch length anchors had a hysteretic energy 3.1 times that of the post tensioned-only bent. Post tensioned-only bent had a residual drift ratio of 0.9%. The residual drift ratio of 1.1% for bent with stretch length anchros and 2.3% for bent with buckling restrained brace .
Abstract Experimental results for a re-centering bridge bent whose concrete columns were post-tensioned with unbonded high-strength steel bars are presented. The initial post-tensioning forces to achieve column re-centering were obtained using rigid body analogy. Steel collars were provided at the top and bottom ends of the columns for confinement. The column-to-footing interface contained a polyurethane layer inside the shear key to reduce column damage. For the initial post-tensioning forces implemented in the experiment, concrete damage was observed at the bottom of the columns. The post-tensioned (PT) bars remained elastic up to the design drift ratio of 2.0% and yielded at a 5.0% drift ratio; the column longitudinal mild steel bars yielded at a drift ratio of 6.0%. The performance of the post-tensioned bridge bent without any external energy dissipators (PT-Only bent) was compared with that of two similar hybrid bridge bents reinforced with external energy dissipators: the first incorporating tension-only stretch length anchors, and the second incorporating a buckling restrained brace. The two hybrid bents displayed excellent performance compared to the PT-Only bent in terms of strength, stiffness, and hysteretic energy dissipation; however, the PT-Only bent had a superior re-centering efficiency compared to the two hybrid bents.
Experimental evaluation of post-tensioned bridge bent under cyclic loads and comparison to hybrid bridge bents
Dangol, I. (author) / Thapa, D. (author) / Pantelides, C.P. (author)
Engineering Structures ; 256
2022-01-29
Article (Journal)
Electronic Resource
English
Testing and analysis of concrete bridge bents with post-tensioned seismic retrofits
British Library Conference Proceedings | 1996
|Simulation of post-tensioned bridge columns under reversed-cyclic loads
Online Contents | 2015
|Simulation of post-tensioned bridge columns under reversed-cyclic loads
Springer Verlag | 2015
|Simulation of post-tensioned bridge columns under reversed-cyclic loads
British Library Online Contents | 2016
|