Thermal comfort and passive survivability in earthen buildings
Abstract Earthen building materials have been regaining popularity due to their environmental, economic, and health advantages. Furthermore, given projected thermal survivability in the face of climate change, passive strategies that minimize use of fossil fuels for operational space conditioning are becoming increasingly necessary. Using the lens of passive survivability, this research investigates the abilities of four earthen wall assemblies (cob, light straw clay, unstabilized rammed earth, insulated unstabilized rammed earth) and three conventional assemblies (concrete masonry unit (CMU), insulated CMU, insulated wood frame) to provide adaptive thermal comfort in six distinct climates, with and without passive heating and cooling systems. Residential dwellings were evaluated through simulation with heat and moisture transport algorithms, showing that passive conditioning is especially beneficial with earth assemblies, bringing 25–70% of uncomfortable annual hours into the adaptive comfort zone, alongside strikingly lower diurnal temperature swings in all examined climates, and in all seasons, than conventional walls. Further investigation into the heat and moisture fluxes reveals that the thermal stability of the earth dwellings is provided in part by moisture sorption and evaporation. Together, for the first time, these results show that the thermal performance of earth assemblies can, with well-designed passive heating and cooling strategies, equal or outperform conventional assemblies in a range of U.S. climates, supporting their expanded inclusion in U.S. building codes. This research provides a novel contribution to the thermal performance optimization of earth construction, critically linking thermal and hygroscopic performance with passive design strategies such as shading, natural ventilation, and movable insulation.
Graphical abstract Display Omitted
Highlights The hygrothermal behavior of earth and conventional walls is compared in 6 climates. Passive heating and cooling improve comfort and survivability in all cases. Insulated earthen dwellings provide the most annual hours of adaptive comfort. Earthen dwellings with passive conditioning show the greatest thermal stability. Latent and sensible heat fluxes combine to provide this high thermal performance.
Thermal comfort and passive survivability in earthen buildings
Abstract Earthen building materials have been regaining popularity due to their environmental, economic, and health advantages. Furthermore, given projected thermal survivability in the face of climate change, passive strategies that minimize use of fossil fuels for operational space conditioning are becoming increasingly necessary. Using the lens of passive survivability, this research investigates the abilities of four earthen wall assemblies (cob, light straw clay, unstabilized rammed earth, insulated unstabilized rammed earth) and three conventional assemblies (concrete masonry unit (CMU), insulated CMU, insulated wood frame) to provide adaptive thermal comfort in six distinct climates, with and without passive heating and cooling systems. Residential dwellings were evaluated through simulation with heat and moisture transport algorithms, showing that passive conditioning is especially beneficial with earth assemblies, bringing 25–70% of uncomfortable annual hours into the adaptive comfort zone, alongside strikingly lower diurnal temperature swings in all examined climates, and in all seasons, than conventional walls. Further investigation into the heat and moisture fluxes reveals that the thermal stability of the earth dwellings is provided in part by moisture sorption and evaporation. Together, for the first time, these results show that the thermal performance of earth assemblies can, with well-designed passive heating and cooling strategies, equal or outperform conventional assemblies in a range of U.S. climates, supporting their expanded inclusion in U.S. building codes. This research provides a novel contribution to the thermal performance optimization of earth construction, critically linking thermal and hygroscopic performance with passive design strategies such as shading, natural ventilation, and movable insulation.
Graphical abstract Display Omitted
Highlights The hygrothermal behavior of earth and conventional walls is compared in 6 climates. Passive heating and cooling improve comfort and survivability in all cases. Insulated earthen dwellings provide the most annual hours of adaptive comfort. Earthen dwellings with passive conditioning show the greatest thermal stability. Latent and sensible heat fluxes combine to provide this high thermal performance.
Thermal comfort and passive survivability in earthen buildings
Ben-Alon, Lola (author) / Rempel, Alexandra R. (author)
Building and Environment ; 238
2023-04-19
Article (Journal)
Electronic Resource
English
Thermal performance and comfort of vernacular earthen buildings in Egypt and Portugal
BASE | 2018
|Materials selection for thermal comfort in passive solar buildings
British Library Online Contents | 2006
|Study on the Green Earthen Buildings
Trans Tech Publications | 2013
|