Preliminary assessment of BTEX concentrations in indoor air of residential buildings and atmospheric ambient air in Ardabil, Iran
Abstract BTEX concentrations in indoor and outdoor air of 50 homes were studied in Ardabil city and their influencing parameters including; heating system, using gas stove and samovar, tobacco smoking, the floors in which the monitored homes were located, and kitchen plan were considered in the study. Risk assessment analysis was carried out with the obtained concentrations based on EPA IRIS reference doses. BTEX compounds were sampled by charcoal tubes and the samples were analyzed by a GC-FID. Concentrations of benzene (15.18 μg/m3 vs. 8.65 μg/m3), toluene (69.70 μg/m3 vs. 40.56 μg/m3), ethylbenzene (12.07 μg/m3 vs. 4.92 μg/m3) and xylene (48.08 μg/m3 vs. 7.44 μg/m3) in indoor air were significantly (p < 0.05) higher than the levels quantified for outdoor air. The obtained concentrations of benzene were considerably higher than the recommended value of 5 μg/m3 established by Iran environmental protection organization. Among the BTEX compounds, benzene (HQ = 0.51) and xylene (HQ = 0.47) had notable hazard quotient and were the main pollutants responsible for high hazard index in the monitored homes (HI = 1.003). The results showed considerably high cancer risk for lifetime exposure to the indoor (125 × 10−6) and outdoor (71 × 10−6) benzene. Indoor benzene concentrations in homes were significantly influenced by type of heating system, story, and natural gas appliances.
Highlights Benzene mean concentration of 15.22 μg/m3 was high compared to recommended limit. The expected cancer risk of 125 × 10−6 was obtained for benzene exposure in the indoor. Total hazard index for benzene long-term exposure was considerably high (HI = 1.003). Among the BTEX only benzene hazard quotient (HQ-indoor = 0.51) and xylene (HQ-outdoor = 0.47) exceeded the acceptable level. Indoor benzene concentrations were influenced by type of heating system, story, and natural gas using appliances.
Preliminary assessment of BTEX concentrations in indoor air of residential buildings and atmospheric ambient air in Ardabil, Iran
Abstract BTEX concentrations in indoor and outdoor air of 50 homes were studied in Ardabil city and their influencing parameters including; heating system, using gas stove and samovar, tobacco smoking, the floors in which the monitored homes were located, and kitchen plan were considered in the study. Risk assessment analysis was carried out with the obtained concentrations based on EPA IRIS reference doses. BTEX compounds were sampled by charcoal tubes and the samples were analyzed by a GC-FID. Concentrations of benzene (15.18 μg/m3 vs. 8.65 μg/m3), toluene (69.70 μg/m3 vs. 40.56 μg/m3), ethylbenzene (12.07 μg/m3 vs. 4.92 μg/m3) and xylene (48.08 μg/m3 vs. 7.44 μg/m3) in indoor air were significantly (p < 0.05) higher than the levels quantified for outdoor air. The obtained concentrations of benzene were considerably higher than the recommended value of 5 μg/m3 established by Iran environmental protection organization. Among the BTEX compounds, benzene (HQ = 0.51) and xylene (HQ = 0.47) had notable hazard quotient and were the main pollutants responsible for high hazard index in the monitored homes (HI = 1.003). The results showed considerably high cancer risk for lifetime exposure to the indoor (125 × 10−6) and outdoor (71 × 10−6) benzene. Indoor benzene concentrations in homes were significantly influenced by type of heating system, story, and natural gas appliances.
Highlights Benzene mean concentration of 15.22 μg/m3 was high compared to recommended limit. The expected cancer risk of 125 × 10−6 was obtained for benzene exposure in the indoor. Total hazard index for benzene long-term exposure was considerably high (HI = 1.003). Among the BTEX only benzene hazard quotient (HQ-indoor = 0.51) and xylene (HQ-outdoor = 0.47) exceeded the acceptable level. Indoor benzene concentrations were influenced by type of heating system, story, and natural gas using appliances.
Preliminary assessment of BTEX concentrations in indoor air of residential buildings and atmospheric ambient air in Ardabil, Iran
Hazrati, Sadegh (author) / Rostami, Roohollah (author) / Farjaminezhad, Manoochehr (author) / Fazlzadeh, Mehdi (author)
Atmospheric Environment ; 132 ; 91-97
2016-02-25
7 pages
Article (Journal)
Electronic Resource
English
Automobile proximity and indoor residential concentrations of BTEX and MTBE
British Library Online Contents | 2011
|Automobile proximity and indoor residential concentrations of BTEX and MTBE
Online Contents | 2011
|Revealing source signatures in ambient BTEX concentrations
Online Contents | 2008
|Revealing source signatures in ambient BTEX concentrations
Online Contents | 2008
|