A platform for research: civil engineering, architecture and urbanism
Behaviour and confinement mechanism of circular concrete-filled aluminum alloy tubular stub columns under axial compression
Abstract Concrete-filled steel tubes are widely applied in offshore structures, which often being exposed to aggressive ocean climate. This has recently led to the introduction of concrete-filled aluminum alloy tubular (CFAT) columns, of which aluminum alloy tube is used as a superior anti-corrosion metal material. However, limited research has led to the design of CFAT columns not being included in the current design specifications, limiting their engineering applications. Accordingly, in this paper, an experimental program including 9 CFAT specimens was launched to further investigate the compressive behavior of CFAT short columns and to clarify the confinement mechanism in such columns. The test results indicate that the ultimate capacity of CFAT short columns is improved with the increase of concrete strength or the decrease of tube diameter-to-wall thickness ratio. Based on the experimental results, the finite element model (FEM) was established, and then used to clarify the confinement mechanism of CFAT columns and investigate the effects of the salient parameters on the behavior of such columns. By comparing with the existing experimental results, the accuracy of current strength calculation formulas for CFAT columns was assessed, and the conclusion indicates that there is an unexpected deviation in the prediction results. To this end, a simplified strength prediction formula for CFAT columns was proposed, which successfully introduced a novel confinement factor that well reflects the confinement effect of the concrete core. This confinement factor considers the effects of proof stress, concrete strength, and tube diameter-to-wall thickness ratio. Finally, compared with other formulas, the proposed formula has better performance in predicting results.
Highlights An experimental program including 9 CFAT specimens is launched. The FE model is established and validated against the experimental results. A novel confinement factor considering salient variables is suggested. A simplified strength prediction formula for CFAT columns is proposed. The proposed formula exhibits good predictive performance.
Behaviour and confinement mechanism of circular concrete-filled aluminum alloy tubular stub columns under axial compression
Abstract Concrete-filled steel tubes are widely applied in offshore structures, which often being exposed to aggressive ocean climate. This has recently led to the introduction of concrete-filled aluminum alloy tubular (CFAT) columns, of which aluminum alloy tube is used as a superior anti-corrosion metal material. However, limited research has led to the design of CFAT columns not being included in the current design specifications, limiting their engineering applications. Accordingly, in this paper, an experimental program including 9 CFAT specimens was launched to further investigate the compressive behavior of CFAT short columns and to clarify the confinement mechanism in such columns. The test results indicate that the ultimate capacity of CFAT short columns is improved with the increase of concrete strength or the decrease of tube diameter-to-wall thickness ratio. Based on the experimental results, the finite element model (FEM) was established, and then used to clarify the confinement mechanism of CFAT columns and investigate the effects of the salient parameters on the behavior of such columns. By comparing with the existing experimental results, the accuracy of current strength calculation formulas for CFAT columns was assessed, and the conclusion indicates that there is an unexpected deviation in the prediction results. To this end, a simplified strength prediction formula for CFAT columns was proposed, which successfully introduced a novel confinement factor that well reflects the confinement effect of the concrete core. This confinement factor considers the effects of proof stress, concrete strength, and tube diameter-to-wall thickness ratio. Finally, compared with other formulas, the proposed formula has better performance in predicting results.
Highlights An experimental program including 9 CFAT specimens is launched. The FE model is established and validated against the experimental results. A novel confinement factor considering salient variables is suggested. A simplified strength prediction formula for CFAT columns is proposed. The proposed formula exhibits good predictive performance.
Behaviour and confinement mechanism of circular concrete-filled aluminum alloy tubular stub columns under axial compression
Yan, Xi-Feng (author) / Lin, Siqi (author) / Zhao, Yan-Gang (author)
Marine Structures ; 95
2024-02-05
Article (Journal)
Electronic Resource
English
Analytical behavior of concrete-filled aluminum tubular stub columns under axial compression
TIBKAT | 2018
|Behaviour of square concrete-filled stiffened steel tubular stub columns under axial compression
SAGE Publications | 2019
|