A platform for research: civil engineering, architecture and urbanism
Development and evaluation of personal respirable particulate sampler (PRPS)
AbstractThis paper presents the development, laboratory evaluation, and field tests of a personal respirable particulate sampler (PRPS). The PRPS is designed as a personal sampling system to collect particulate matter (PM0.5, PM1.0, PM2.5, PM4.5, and PM10) and gaseous pollutants, including O3, SO2, and NO2. It operates at a flow rate of 5.0LPM and consists of five selectable impaction stages (with cutpoints of 10, 4.5, 2.5, 1.0, and 0.5μm), a backup filter, and two diffusion passive samplers. In each impaction stage, particles are collected onto a polyurethane foam (PUF) substrate. This substrate, using no adhesive, was shown to have minimum particle bounce and re-entrainment. A backup 37mm Teflon membrane filter is used downstream to collect particles smaller than the cutoff diameter of the final impaction stage. The impaction stage cutpoints were characterized in the laboratory using artificially generated polydisperse aerosols. Particle losses for each stage were found to be acceptably low. The performance of the PRPS was also compared with that of a collocated micro-orifice cascade impactor (MOI) and real-time particle sizing instruments (SMPS/APS) in laboratory experiments using artificially generated particles. The size distributions measured by the PRPS were found to be much closer to those measured by the real-time particle sizing instruments than to those measured by the MOI. A field PM intercomparison study was also conducted using the PRPS and three reference samplers, the Harvard Impactor (HI), the USEPA PM2.5 Well Impactor Ninety Six (WINS), and the Harvard Personal Environmental Monitor (Harvard PEM) sampler. The PM10, PM2.5, and sulfate concentrations measured by PRPS were in a very good agreement with those obtained from the reference samplers.
Development and evaluation of personal respirable particulate sampler (PRPS)
AbstractThis paper presents the development, laboratory evaluation, and field tests of a personal respirable particulate sampler (PRPS). The PRPS is designed as a personal sampling system to collect particulate matter (PM0.5, PM1.0, PM2.5, PM4.5, and PM10) and gaseous pollutants, including O3, SO2, and NO2. It operates at a flow rate of 5.0LPM and consists of five selectable impaction stages (with cutpoints of 10, 4.5, 2.5, 1.0, and 0.5μm), a backup filter, and two diffusion passive samplers. In each impaction stage, particles are collected onto a polyurethane foam (PUF) substrate. This substrate, using no adhesive, was shown to have minimum particle bounce and re-entrainment. A backup 37mm Teflon membrane filter is used downstream to collect particles smaller than the cutoff diameter of the final impaction stage. The impaction stage cutpoints were characterized in the laboratory using artificially generated polydisperse aerosols. Particle losses for each stage were found to be acceptably low. The performance of the PRPS was also compared with that of a collocated micro-orifice cascade impactor (MOI) and real-time particle sizing instruments (SMPS/APS) in laboratory experiments using artificially generated particles. The size distributions measured by the PRPS were found to be much closer to those measured by the real-time particle sizing instruments than to those measured by the MOI. A field PM intercomparison study was also conducted using the PRPS and three reference samplers, the Harvard Impactor (HI), the USEPA PM2.5 Well Impactor Ninety Six (WINS), and the Harvard Personal Environmental Monitor (Harvard PEM) sampler. The PM10, PM2.5, and sulfate concentrations measured by PRPS were in a very good agreement with those obtained from the reference samplers.
Development and evaluation of personal respirable particulate sampler (PRPS)
Lee, Seung Joo (author) / Demokritou, Philip (author) / Koutrakis, Petros (author) / Delgado-Saborit, Juana M. (author)
Atmospheric Environment ; 40 ; 212-224
2005-08-16
13 pages
Article (Journal)
Electronic Resource
English
Personal respirable dust sampler /by M. Jacobsen; J.A. Lamonica
TIBKAT | 1969
|EPA notifies 950 PRPs of on clean-up liability
Online Contents | 1998
North America - EPA offers settlement to >800 PRPs for Casmalia clean-up
Online Contents | 1999
The Application of Light Scattering Dust Sampler in Indoor Respirable Particles PM~1~0 Measurement
British Library Conference Proceedings | 2004
|