Detuning of wind-induced vibrations of cooling tower shells
AbstractDetuning of wind-induced vibrations of cooling tower shells can be achieved through adequately stiff upper edge members. In this case and for double layer reinforcement bending resistance may be sufficient within the usual minimum reinforcement /5/. However, if the cornice stiffness is too weak the required bending reinforcement can exceed the prescribed minimum values by far (Fig. 8). Cracking and thus reduced durability of the cooling tower shell can not be excluded.
Detuning of wind-induced vibrations of cooling tower shells
AbstractDetuning of wind-induced vibrations of cooling tower shells can be achieved through adequately stiff upper edge members. In this case and for double layer reinforcement bending resistance may be sufficient within the usual minimum reinforcement /5/. However, if the cornice stiffness is too weak the required bending reinforcement can exceed the prescribed minimum values by far (Fig. 8). Cracking and thus reduced durability of the cooling tower shell can not be excluded.
Detuning of wind-induced vibrations of cooling tower shells
Krätzig, Wilfried B. (author) / Sanal, Ziya (author)
1988-01-01
7 pages
Article (Journal)
Electronic Resource
English
Wind Buckling of Natural Draught Cooling Tower Shells
British Library Conference Proceedings | 1994
|Defining design wind loads on RC cooling tower shells
British Library Conference Proceedings | 2004
|Ultimate strength of RC cooling tower shells subjected to wind load
Online Contents | 1994
|Ultimate strength of RC cooling tower shells subjected to wind load
Elsevier | 1994
|