A platform for research: civil engineering, architecture and urbanism
Mass transfer intensification of CO2 absorption in monoethanolamine using high frequency ultrasonic technology in continuous system
Graphical abstract Display Omitted
Highlights CO2 removal from natural gas using a novel high frequency ultrasonic absorption (HiFUA) system in continuous operation. Parametric study on the mass transfer coefficient was conducted and the optimum condition was identified. A quadratic model that was developed using CCD coupled with RSM successfully predicted the mass transfer coefficient. The presence of ultrasonic irradiation enhances the mass transfer 7 times higher than without ultrasonic irradiation. HiFUA demonstrated 12 times higher absorption performance than packed column for CO2 removal using monoethanolamine.
Abstract Intensification technology for absorption process is of interest for the separation of CO2 from natural gas in the offshore. High frequency ultrasonic absorption technology in batch system has shown remarkable potential for offshore application due to high operating flexibility and mass transfer performance. Therefore, in this work, a high frequency ultrasonic absorption (HiFUA) of CO2 from natural gas using monoethanolamine is proposed for continuous system to suit the industrial mode of operation. The effect of the operating parameters on the overall mass transfer coefficient was investigated, thus the optimum condition was identified using central composite design coupled with response surface methodology. Based on the results, the optimum condition was found at the gas flow rate of 30 SLPM, liquid flow rate of 0.15 SLPM, pressure of 10 bar and ultrasonic voltage of 30 V, which resulted to maximum mass transfer coefficient of 268.9 mol/kPa.m3.hr. The presence of high frequency ultrasonic irradiation has enhanced the absorption process 7 times higher as compared to the case of without ultrasonic irradiation due to its physical effects which are the acoustic streaming, fountain and atomization. The enhancement in continuous system is lower than the batch system reported in the literature due to the difference in the reactor configuration. Nevertheless, HiFUA has intensified the mass transfer performance 12 times higher as compared to conventional packed bed column for CO2-MEA system. This work has shown great potential of high frequency ultrasonic irradiation as an intensification technology for CO2 absorption process.
Mass transfer intensification of CO2 absorption in monoethanolamine using high frequency ultrasonic technology in continuous system
Graphical abstract Display Omitted
Highlights CO2 removal from natural gas using a novel high frequency ultrasonic absorption (HiFUA) system in continuous operation. Parametric study on the mass transfer coefficient was conducted and the optimum condition was identified. A quadratic model that was developed using CCD coupled with RSM successfully predicted the mass transfer coefficient. The presence of ultrasonic irradiation enhances the mass transfer 7 times higher than without ultrasonic irradiation. HiFUA demonstrated 12 times higher absorption performance than packed column for CO2 removal using monoethanolamine.
Abstract Intensification technology for absorption process is of interest for the separation of CO2 from natural gas in the offshore. High frequency ultrasonic absorption technology in batch system has shown remarkable potential for offshore application due to high operating flexibility and mass transfer performance. Therefore, in this work, a high frequency ultrasonic absorption (HiFUA) of CO2 from natural gas using monoethanolamine is proposed for continuous system to suit the industrial mode of operation. The effect of the operating parameters on the overall mass transfer coefficient was investigated, thus the optimum condition was identified using central composite design coupled with response surface methodology. Based on the results, the optimum condition was found at the gas flow rate of 30 SLPM, liquid flow rate of 0.15 SLPM, pressure of 10 bar and ultrasonic voltage of 30 V, which resulted to maximum mass transfer coefficient of 268.9 mol/kPa.m3.hr. The presence of high frequency ultrasonic irradiation has enhanced the absorption process 7 times higher as compared to the case of without ultrasonic irradiation due to its physical effects which are the acoustic streaming, fountain and atomization. The enhancement in continuous system is lower than the batch system reported in the literature due to the difference in the reactor configuration. Nevertheless, HiFUA has intensified the mass transfer performance 12 times higher as compared to conventional packed bed column for CO2-MEA system. This work has shown great potential of high frequency ultrasonic irradiation as an intensification technology for CO2 absorption process.
Mass transfer intensification of CO2 absorption in monoethanolamine using high frequency ultrasonic technology in continuous system
Yusof, Siti Munirah Mhd (author) / Shariff, Azmi Mohd (author) / Tay, Wee Horng (author) / Lau, Kok Keong (author) / Mustafa, Nur Farhana Ajua (author)
2020-09-01
Article (Journal)
Electronic Resource
English
Enhancement of CO2 Absorption Process Using High-Frequency Ultrasonic Waves
DOAJ | 2023
|