AbstractThe wind blowing on a building causes overpressures and underpressures which vary over its surface, over time and according to the direction from which the wind is coming. The distributions of over- and underpressure on the surfaces where natural smoke and heat ventilators may be located are described. Simple means to calculate the extreme wind pressure acting on a ventilator in Europe is detailed and a table of possible values encountered in design is presented.In order to respond to this wind loading, the means to assess the resistance to wind of ventilators in closed and open position are reviewed, in particular, the testing method established by UEAtc for the agrément of elements of the envelope of a building.Finally the problem of safety factors to be applied in the case of closed and open ventilator is discussed.
RésuméLe vent soufflant sur un bâtiment crée des surpressions et des dépressions qui varient sur sa surface, dans le temps et selon la direction d'où vient le vent. Les distributions des surpressions et des dépressions sur les surfaces où des exutoires de fumée et de chaleur naturels peuvent se trouver sont décrites. Une méthode de calcul simple de la pression extrême de vent susceptible d'agir sur un exutoire en Europe est détaillée et un tableau des valeurs de pression couramment rencontrées dans la pratique est présenté.Pour répondre à ces charges de vent, les méthodes de détermination de la résistance au vent des exutoires en position fermée et ouverte sont examinées, en particulier la méthode d'essai établie par l'UEAtc pour l'agrément des éléments de l'enveloppe d'un bâtiment.
AbstractThe wind blowing on a building causes overpressures and underpressures which vary over its surface, over time and according to the direction from which the wind is coming. The distributions of over- and underpressure on the surfaces where natural smoke and heat ventilators may be located are described. Simple means to calculate the extreme wind pressure acting on a ventilator in Europe is detailed and a table of possible values encountered in design is presented.In order to respond to this wind loading, the means to assess the resistance to wind of ventilators in closed and open position are reviewed, in particular, the testing method established by UEAtc for the agrément of elements of the envelope of a building.Finally the problem of safety factors to be applied in the case of closed and open ventilator is discussed.
RésuméLe vent soufflant sur un bâtiment crée des surpressions et des dépressions qui varient sur sa surface, dans le temps et selon la direction d'où vient le vent. Les distributions des surpressions et des dépressions sur les surfaces où des exutoires de fumée et de chaleur naturels peuvent se trouver sont décrites. Une méthode de calcul simple de la pression extrême de vent susceptible d'agir sur un exutoire en Europe est détaillée et un tableau des valeurs de pression couramment rencontrées dans la pratique est présenté.Pour répondre à ces charges de vent, les méthodes de détermination de la résistance au vent des exutoires en position fermée et ouverte sont examinées, en particulier la méthode d'essai établie par l'UEAtc pour l'agrément des éléments de l'enveloppe d'un bâtiment.
Détermination de l'action du vent et de la résistance au vent des exutoires de fumée et de chaleur naturels
Spehl, P. (author)
Journal of Wind Engineering and Industrial Aerodynamics ; 45 ; 275-288
1993-01-01
14 pages
Article (Journal)
Electronic Resource
French
L'action du vent sur les constructions