A platform for research: civil engineering, architecture and urbanism
Determination of beryllium concentrations in UK ambient air
Abstract Air quality monitoring of ambient air is essential to minimise the exposure of the general population to toxic substances such as heavy metals, and thus the health risks associated with them. In the UK, ambient air is already monitored under the UK Heavy Metals Monitoring Network for a number of heavy metals, including nickel (Ni), arsenic (As), cadmium (Cd) and lead (Pb) to ensure compliance with legislative limits. However, the UK Expert Panel on Air Quality Standards (EPAQS) has highlighted a need to limit concentrations of beryllium (Be) in air, which is not currently monitored, because of its toxicity. The aim of this work was to analyse airborne particulate matter (PM) sampled onto filter papers from the UK Heavy Metals Monitoring Network for quantitative, trace level beryllium determination and compare the results to the guideline concentration specified by EPAQS. Samples were prepared by microwave acid digestion in a matrix of 2% sulphuric acid and 14% nitric acid, verified by the use of Certified Reference Materials (CRMs). The digested samples were then analysed by Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The filters from the UK Heavy Metals Monitoring Network were tested using this procedure and the average beryllium concentration across the network for the duration of the study period was 7.87 pg m−3. The highest site average concentration was 32.0 pg m−3 at Scunthorpe Low Santon, which is significantly lower than levels that are thought to cause harm. However the highest levels were observed at sites monitoring industrial point sources, indicating that beryllium is being used and emitted, albeit at very low levels, from these point sources. Comparison with other metals concentrations and data from the UK National Atmospheric Emissions Inventory suggests that current emissions of beryllium may be significantly overestimated.
Highlights Ambient UK air filter samples were analysed by ICP-MS for beryllium content. The samples were provided by the UK Heavy Metals Monitoring Network. Measured beryllium concentrations were significantly below the guidance threshold. Current atmospheric beryllium emissions may be overestimated. Future monitoring could target specific sources of beryllium emissions.
Determination of beryllium concentrations in UK ambient air
Abstract Air quality monitoring of ambient air is essential to minimise the exposure of the general population to toxic substances such as heavy metals, and thus the health risks associated with them. In the UK, ambient air is already monitored under the UK Heavy Metals Monitoring Network for a number of heavy metals, including nickel (Ni), arsenic (As), cadmium (Cd) and lead (Pb) to ensure compliance with legislative limits. However, the UK Expert Panel on Air Quality Standards (EPAQS) has highlighted a need to limit concentrations of beryllium (Be) in air, which is not currently monitored, because of its toxicity. The aim of this work was to analyse airborne particulate matter (PM) sampled onto filter papers from the UK Heavy Metals Monitoring Network for quantitative, trace level beryllium determination and compare the results to the guideline concentration specified by EPAQS. Samples were prepared by microwave acid digestion in a matrix of 2% sulphuric acid and 14% nitric acid, verified by the use of Certified Reference Materials (CRMs). The digested samples were then analysed by Inductively Coupled Plasma Mass Spectrometry (ICP-MS). The filters from the UK Heavy Metals Monitoring Network were tested using this procedure and the average beryllium concentration across the network for the duration of the study period was 7.87 pg m−3. The highest site average concentration was 32.0 pg m−3 at Scunthorpe Low Santon, which is significantly lower than levels that are thought to cause harm. However the highest levels were observed at sites monitoring industrial point sources, indicating that beryllium is being used and emitted, albeit at very low levels, from these point sources. Comparison with other metals concentrations and data from the UK National Atmospheric Emissions Inventory suggests that current emissions of beryllium may be significantly overestimated.
Highlights Ambient UK air filter samples were analysed by ICP-MS for beryllium content. The samples were provided by the UK Heavy Metals Monitoring Network. Measured beryllium concentrations were significantly below the guidance threshold. Current atmospheric beryllium emissions may be overestimated. Future monitoring could target specific sources of beryllium emissions.
Determination of beryllium concentrations in UK ambient air
Goddard, Sharon L. (author) / Brown, Richard J.C. (author) / Ghatora, Baljit K. (author)
Atmospheric Environment ; 147 ; 320-329
2016-10-10
10 pages
Article (Journal)
Electronic Resource
English
Beryllium-7 aerosols in ambient air
Online Contents | 1996
|Beryllium and beryllium alloys
Engineering Index Backfile | 1936
|Beryllium and beryllium alloys
Engineering Index Backfile | 1936
|Radial diffusive sampler for the determination of 8-h ambient ozone concentrations
Online Contents | 2007
|Determination of Source Contributions to Ambient Volatile Organic Compound Concentrations in Berlin
Taylor & Francis Verlag | 1999
|