A platform for research: civil engineering, architecture and urbanism
Punching shear strength of interior concrete slab–column connections reinforced with steel fibers
AbstractA theoretical study was performed to investigate the punching shear strength of interior slab–column connections made of steel fiber reinforced concrete (FRC). In the steel FRC slab–column connection, the shear force applied to the critical section is resisted by both the compression zone and the tension zone at the critical section. The shear capacity of the compression zone was defined by considering the interaction between the shear and the normal stresses developed at the critical section. The shear capacity of the tension zone was defined by considering the post-cracking tensile strength of FRC. By using the shear capacity, a new strength model for the punching shear strength of steel FRC slab–column connections was developed. The proposed strength model was verified using existing test results and showed very good accuracy. For convenience in design, a simplified design equation was also developed.
Punching shear strength of interior concrete slab–column connections reinforced with steel fibers
AbstractA theoretical study was performed to investigate the punching shear strength of interior slab–column connections made of steel fiber reinforced concrete (FRC). In the steel FRC slab–column connection, the shear force applied to the critical section is resisted by both the compression zone and the tension zone at the critical section. The shear capacity of the compression zone was defined by considering the interaction between the shear and the normal stresses developed at the critical section. The shear capacity of the tension zone was defined by considering the post-cracking tensile strength of FRC. By using the shear capacity, a new strength model for the punching shear strength of steel FRC slab–column connections was developed. The proposed strength model was verified using existing test results and showed very good accuracy. For convenience in design, a simplified design equation was also developed.
Punching shear strength of interior concrete slab–column connections reinforced with steel fibers
Choi, Kyoung-Kyu (author) / Reda Taha, Mahmoud M. (author) / Park, Hong-Gun (author) / Maji, Arup K. (author)
Cement and Concrete Composites ; 29 ; 409-420
2006-12-14
12 pages
Article (Journal)
Electronic Resource
English
Punching shear strength of interior concrete slab–column connections reinforced with steel fibers
Online Contents | 2007
|Punching Shear Resistance of Interior GFRP Reinforced Slab-Column Connections
Online Contents | 2013
|Punching Shear Resistance of Interior GFRP Reinforced Slab-Column Connections
British Library Online Contents | 2013
|