A platform for research: civil engineering, architecture and urbanism
Experimental study of flexural critical reinforced concrete filled composite plate shear walls
Highlights Four innovative flexural critical composite shear walls without tie bars were proposed and tested. The failure mode, load-displacement relationship and stiffness degradation behavior were investigated. The proposed systems connected by shear studs exhibited adequate strength and displacement capacity. The shear force contribution of steel plate was obtained and overstrength ratio was proposed.
Abstract The reinforced concrete filled composite plate shear walls (CPSW) system employs two steel plates with infilled reinforced concrete. Based on an experimental study of four flexural critical CPSW specimens under high axial compression ratio ranging from 0.313 to 0.542 and reciprocal lateral load, the seismic performance of shear studs connected CPSW systems with orthogonal reinforcement in wall web and longitudinal reinforcement in boundary element is examined. The failure mode, load-displacement relationship, flexural strength, displacement capacity, stiffness degradation and equivalent damping ratio are reported in detail. The compression yielding of boundary element was observed before its local buckling, and yielding of faceplate was observed before faceplate local buckling. The fracture failure of the boundary element and crushing of infilled concrete were observed at the descending branch. The test results showed that the CPSW systems connected by shear studs had adequate ductility, and the ultimate drift ratio ranged from 1.17% to 1.78%. The overstrength ratio of the moment capacity ranged from 1.06 to 1.18 in the test. Based on the plasticity theory, the strain measurement results of steel faceplates were used to calculate the shear force contribution of the steel plate. The influence of axial compression ratio on the internal force transfer and ultimate capacity is investigated. In addition, a database of 47 flexural critical CPSW specimens with boundary element was established, and the overstrength ratio for the anchorage design was proposed with adequate safety.
Experimental study of flexural critical reinforced concrete filled composite plate shear walls
Highlights Four innovative flexural critical composite shear walls without tie bars were proposed and tested. The failure mode, load-displacement relationship and stiffness degradation behavior were investigated. The proposed systems connected by shear studs exhibited adequate strength and displacement capacity. The shear force contribution of steel plate was obtained and overstrength ratio was proposed.
Abstract The reinforced concrete filled composite plate shear walls (CPSW) system employs two steel plates with infilled reinforced concrete. Based on an experimental study of four flexural critical CPSW specimens under high axial compression ratio ranging from 0.313 to 0.542 and reciprocal lateral load, the seismic performance of shear studs connected CPSW systems with orthogonal reinforcement in wall web and longitudinal reinforcement in boundary element is examined. The failure mode, load-displacement relationship, flexural strength, displacement capacity, stiffness degradation and equivalent damping ratio are reported in detail. The compression yielding of boundary element was observed before its local buckling, and yielding of faceplate was observed before faceplate local buckling. The fracture failure of the boundary element and crushing of infilled concrete were observed at the descending branch. The test results showed that the CPSW systems connected by shear studs had adequate ductility, and the ultimate drift ratio ranged from 1.17% to 1.78%. The overstrength ratio of the moment capacity ranged from 1.06 to 1.18 in the test. Based on the plasticity theory, the strain measurement results of steel faceplates were used to calculate the shear force contribution of the steel plate. The influence of axial compression ratio on the internal force transfer and ultimate capacity is investigated. In addition, a database of 47 flexural critical CPSW specimens with boundary element was established, and the overstrength ratio for the anchorage design was proposed with adequate safety.
Experimental study of flexural critical reinforced concrete filled composite plate shear walls
Nie, Xin (author) / Wang, Jia-Ji (author) / Tao, Mu-Xuan (author) / Fan, Jian-Sheng (author) / Bu, Fan-Min (author)
Engineering Structures ; 197
2019-07-23
Article (Journal)
Electronic Resource
English
Deformation capacity of concrete-filled steel plate composite shear walls
Online Contents | 2014
|EXPERIMENTAL STUDY OF THE FLEXURAL CAPACITY OF STEEL FIBER PARTIALLY REINFORCED CONCRETE SHEAR WALLS
British Library Conference Proceedings | 2007
|Flexural Modeling of Reinforced Concrete Walls -- Experimental Verification
Online Contents | 2006
|