The impact of wind upon the Pulse technique measured airtightness of a detached dwelling
Abstract The novel Pulse technique measures the building airtightness in a dynamic approach, involving a low-pressure pressurisation process, typically in 1–10Pa. It is known that the wind effect is one of the main sources of uncertainty for airtightness testing. The literature review revealed that the wind impact on measuring building airtightness has been explored in relation to the steady pressurisation method (i.e., the blower door), while there is limited research investigating the validity of the Pulse measurement under various natural wind conditions. In this study, in total, 423 Pulse tests were performed to measure the building airtightness of a five-bedroom dwelling located at the University of Nottingham, UK, under natural wind conditions. The viability of the Pulse technique for delivering airtightness measurements under different wind conditions was assessed, including the impacts of the wind speed and the wind direction on the Pulse measurements. Based on the measured air leakage rates, the threshold of maximum wind speed that led the Pulse measurements to have repeatability greater than ±10% is 5.0 m/s at 2.2 m above ground level (i.e., approximately equivalent to the meteorological wind speed of 7.9 m/s). On the other hand, the directional wind study showed that at lower wind speeds, the wind direction has a lesser influence on the Pulse measurement than the wind speed itself. Practically, multiple Pulse tests are recommended for minimising the wind impact on building airtightness measurement when adverse wind conditions are present.
Highlights •423 Pulse tests were conducted in a UK detached house under natural wind conditions. •Investigations of impacts of wind speed and wind direction on Pulse measurements. •Wind speed limit for the Pulse measurement with uncertainty of ±10% was identified. •Wind direction has a lesser influence on the Pulse measurement than the wind speed. •Multiple Pulse tests are recommended for minimising the wind impact.
The impact of wind upon the Pulse technique measured airtightness of a detached dwelling
Abstract The novel Pulse technique measures the building airtightness in a dynamic approach, involving a low-pressure pressurisation process, typically in 1–10Pa. It is known that the wind effect is one of the main sources of uncertainty for airtightness testing. The literature review revealed that the wind impact on measuring building airtightness has been explored in relation to the steady pressurisation method (i.e., the blower door), while there is limited research investigating the validity of the Pulse measurement under various natural wind conditions. In this study, in total, 423 Pulse tests were performed to measure the building airtightness of a five-bedroom dwelling located at the University of Nottingham, UK, under natural wind conditions. The viability of the Pulse technique for delivering airtightness measurements under different wind conditions was assessed, including the impacts of the wind speed and the wind direction on the Pulse measurements. Based on the measured air leakage rates, the threshold of maximum wind speed that led the Pulse measurements to have repeatability greater than ±10% is 5.0 m/s at 2.2 m above ground level (i.e., approximately equivalent to the meteorological wind speed of 7.9 m/s). On the other hand, the directional wind study showed that at lower wind speeds, the wind direction has a lesser influence on the Pulse measurement than the wind speed itself. Practically, multiple Pulse tests are recommended for minimising the wind impact on building airtightness measurement when adverse wind conditions are present.
Highlights •423 Pulse tests were conducted in a UK detached house under natural wind conditions. •Investigations of impacts of wind speed and wind direction on Pulse measurements. •Wind speed limit for the Pulse measurement with uncertainty of ±10% was identified. •Wind direction has a lesser influence on the Pulse measurement than the wind speed. •Multiple Pulse tests are recommended for minimising the wind impact.
The impact of wind upon the Pulse technique measured airtightness of a detached dwelling
Hsu, Yun-Sheng (author) / Zheng, Xiaofeng (author) / Kraniotis, Dimitrios (author) / Gillott, Mark (author) / Lee, Shin-Ku (author) / Wood, Christopher J. (author)
Building and Environment ; 215
2022-02-27
Article (Journal)
Electronic Resource
English
Airtightness Survey of Detached Wooden Houses in the Hokuriku District
British Library Conference Proceedings | 1994
|REPRESENTING DETACHED DWELLING: A SURVEY
British Library Online Contents | 2002
|Measured Airtightness of an Installed Skylight
British Library Online Contents | 2000
|Dwelling airtightness: A socio-technical evaluation in an Irish context
Online Contents | 2016
|Measured Airtightness of an Installed Skylight
British Library Conference Proceedings | 2000
|