A platform for research: civil engineering, architecture and urbanism
Seismic behavior assessment of fasteners based on a shaking table test of a museum building model with a display case and artifacts
Abstract Fasteners are widely used in museums as an attachment method to secure objects. However, due to the lack of research on the seismic behaviour of fasteners under seismic loads, the implementation of fasteners in museums usually lacks scientific guidance, resulting in their ineffectiveness in improving the seismic safety of museum artifacts. In addition, few studies have experimentally investigated the adverse effects of structural dynamic amplification on the seismic safety of museum artifacts. Therefore, this study aimed to assess the seismic behavior of fasteners used in museums and provide valuable insights for protecting museum artifacts. Shaking table tests were conducted on a full-scale model of a museum building, display case, and artifacts to simulate seismic loads and investigate the seismic response of two typical artifacts secured with fasteners. A numerical study was also performed to evaluate different types of fasteners and their effectiveness in enhancing the seismic safety of artifacts. The adverse effects of dynamic amplification on artifact safety were discussed, and recommendations were provided for improving the seismic behavior of fasteners. Furthermore, the impact of multidirectional seismic excitation on the safety of the artifacts and the seismic performance of the fasteners were analyzed. The research findings contribute to the selection of appropriate fasteners for preserving valuable artifacts in museums.
Graphical Abstract Display Omitted
Highlights A full-size, code-compliant three-story reinforced concrete frame was built to investigate the seismic behavior of fasteners. A comprehensive study was conducted using a shaking table test of a model of the museum building, display case, and artifacts. Different heights and types of fasteners were investigated using numerical analysis to determine the optimal fastener. The adverse effects of dynamic amplification caused by the structure and display case on artifact safety are discussed.
Seismic behavior assessment of fasteners based on a shaking table test of a museum building model with a display case and artifacts
Abstract Fasteners are widely used in museums as an attachment method to secure objects. However, due to the lack of research on the seismic behaviour of fasteners under seismic loads, the implementation of fasteners in museums usually lacks scientific guidance, resulting in their ineffectiveness in improving the seismic safety of museum artifacts. In addition, few studies have experimentally investigated the adverse effects of structural dynamic amplification on the seismic safety of museum artifacts. Therefore, this study aimed to assess the seismic behavior of fasteners used in museums and provide valuable insights for protecting museum artifacts. Shaking table tests were conducted on a full-scale model of a museum building, display case, and artifacts to simulate seismic loads and investigate the seismic response of two typical artifacts secured with fasteners. A numerical study was also performed to evaluate different types of fasteners and their effectiveness in enhancing the seismic safety of artifacts. The adverse effects of dynamic amplification on artifact safety were discussed, and recommendations were provided for improving the seismic behavior of fasteners. Furthermore, the impact of multidirectional seismic excitation on the safety of the artifacts and the seismic performance of the fasteners were analyzed. The research findings contribute to the selection of appropriate fasteners for preserving valuable artifacts in museums.
Graphical Abstract Display Omitted
Highlights A full-size, code-compliant three-story reinforced concrete frame was built to investigate the seismic behavior of fasteners. A comprehensive study was conducted using a shaking table test of a model of the museum building, display case, and artifacts. Different heights and types of fasteners were investigated using numerical analysis to determine the optimal fastener. The adverse effects of dynamic amplification caused by the structure and display case on artifact safety are discussed.
Seismic behavior assessment of fasteners based on a shaking table test of a museum building model with a display case and artifacts
Zou, Xiaoguang (author) / Yang, Weiguo (author) / Liu, Pei (author) / Wang, Meng (author) / Li, Zhouxing (author)
Engineering Structures ; 305
2024-02-15
Article (Journal)
Electronic Resource
English
Seismic slope behavior in a large-scale shaking table model test
Elsevier | 2006
|Seismic slope behavior in a large-scale shaking table model test
British Library Conference Proceedings | 2006
|