A platform for research: civil engineering, architecture and urbanism
Ahorrar: Indoor Occupancy Counting to Enable Smart Energy Efficient Office Buildings
Office buildings have a vast carbon footprint from the energy consumed for heating/cooling, ventilation (HVAC) and lighting. The basic limitation in becoming more energy efficient is in the management of these operations. In particular, the ventilation has been the "holy grail" in building operations and occupancy based control of ventilation can lead to sizeable reduction in energy use. However, building occupancy sensors. generally, report presence or not of occupants and not actual numbers of occupants in the different building zones rather than real occupancy numbers. Hence, ventilation is set to expected, rather than actual, occupancy levels leading to very inefficient building operation. None of the available occupancy based solutions for building automation fully meet the needs of maintenance free adequate accurate occupancy estimation at sufficiently low cost. In this paper, we present Ahorrar, a framework that uses sustainable techniques to inform the occupancy levels in HVAC zone to the building automation system (BAS). Using existing infrastructure and capabilities of consumer devices, Ahorrar can use participatory sensing to compute a real time occupant distribution map within the office building and enable energy saving without additional hardware. In this position paper, we present the building blocks of Ahorrar and the research results that can support the implementation of a sufficiently accurate occupancy mapping system.
Ahorrar: Indoor Occupancy Counting to Enable Smart Energy Efficient Office Buildings
Office buildings have a vast carbon footprint from the energy consumed for heating/cooling, ventilation (HVAC) and lighting. The basic limitation in becoming more energy efficient is in the management of these operations. In particular, the ventilation has been the "holy grail" in building operations and occupancy based control of ventilation can lead to sizeable reduction in energy use. However, building occupancy sensors. generally, report presence or not of occupants and not actual numbers of occupants in the different building zones rather than real occupancy numbers. Hence, ventilation is set to expected, rather than actual, occupancy levels leading to very inefficient building operation. None of the available occupancy based solutions for building automation fully meet the needs of maintenance free adequate accurate occupancy estimation at sufficiently low cost. In this paper, we present Ahorrar, a framework that uses sustainable techniques to inform the occupancy levels in HVAC zone to the building automation system (BAS). Using existing infrastructure and capabilities of consumer devices, Ahorrar can use participatory sensing to compute a real time occupant distribution map within the office building and enable energy saving without additional hardware. In this position paper, we present the building blocks of Ahorrar and the research results that can support the implementation of a sufficiently accurate occupancy mapping system.
Ahorrar: Indoor Occupancy Counting to Enable Smart Energy Efficient Office Buildings
Jain, Shweta (author) / Madamopoulos, Nicholas (author)
2016-10-01
265026 byte
Conference paper
Electronic Resource
English
Post-occupancy evaluation in indoor comfort conditions for green office buildings
DOAJ | 2022
|Pre occupancy evaluation for healthy office buildings
British Library Conference Proceedings | 1995
|Energy-Efficient Office Buildings
British Library Conference Proceedings | 1996
|