A platform for research: civil engineering, architecture and urbanism
Passive motion control of super tall buildings : tuned mass and viscous dampers in Taipei 101.
As tall buildings keep becoming taller, they become more susceptible to dynamic excitations such as wind and seismic excitations. One way to reduce structural vibration under dynamic excitations is by placing damping devices in the buildings. In this thesis, the design concept, design procedure and some current applications of tuned mass and viscous dampers are discussed. Taipei101 was used as an example to compare the performance of the two damping schemes. It was modeled in a two-dimensional scheme in SAP2000 and a TMD was placed on its top to study its effect on the structural response due to wind and seismic excitations and confirm with the actual results. A sensitivity study was then performed to study the effect of varying the mass ratio on the structural response. A second TMD was then placed at the location where the maximum deflection occurs for the second mode to evaluate its effectiveness in reducing structural response. Finally, twelve viscous dampers were placed in the model to study their effects on the structural response. Time-history and steady-state analysis in SAP2000 were used for the wind and seismic analyses.
Passive motion control of super tall buildings : tuned mass and viscous dampers in Taipei 101.
As tall buildings keep becoming taller, they become more susceptible to dynamic excitations such as wind and seismic excitations. One way to reduce structural vibration under dynamic excitations is by placing damping devices in the buildings. In this thesis, the design concept, design procedure and some current applications of tuned mass and viscous dampers are discussed. Taipei101 was used as an example to compare the performance of the two damping schemes. It was modeled in a two-dimensional scheme in SAP2000 and a TMD was placed on its top to study its effect on the structural response due to wind and seismic excitations and confirm with the actual results. A sensitivity study was then performed to study the effect of varying the mass ratio on the structural response. A second TMD was then placed at the location where the maximum deflection occurs for the second mode to evaluate its effectiveness in reducing structural response. Finally, twelve viscous dampers were placed in the model to study their effects on the structural response. Time-history and steady-state analysis in SAP2000 were used for the wind and seismic analyses.
Passive motion control of super tall buildings : tuned mass and viscous dampers in Taipei 101.
Gong, Zheng Li (author)
2009
51, [11] pages
Thesis (M. Eng.)--Massachusetts Institute of Technology, Dept. of Civil and Environmental Engineering, 2009.
Includes bibliographical references (leaves 50-51).
Theses
Electronic Resource
English
COMPACT SLIDING-TYPE TUNED MASS DAMPERS FOR TALL BUILDINGS
TIBKAT | 2020
|Seismic Control of Tall Buildings Using Distributed Multiple Tuned Mass Dampers
DOAJ | 2019
|