A platform for research: civil engineering, architecture and urbanism
Submersible-Type Tainter Gate for Spillway Marseilles Lock and Dam: Hydraulic Model Investigation
A 1:20-scale hydraulic model simulated a 120-ft-wide section of the spillway and stilling basin including one freely suspended 60-ft-wide by 16-ft-high submersible tainter gate. The gate lifting mechanism consisted of a cable at each end of the gate attached to load cells. The magnitude and frequency of the forces acting on the cable supporting each end of the gate were measured. Tests indicated that there was a likelihood of the cables being subjected to exciting forces occurring at a random frequency with flow (a) over and (b) under the subject gate. The magnitude of these forces was about 1 percent of the total gate weight. Discharge characteristics and coefficients and stilling basin performance with various operating scenarios were determined. Keywords: Hydraulic forces, Submersible gates, Spillway, F Vibrations. (aw)
Submersible-Type Tainter Gate for Spillway Marseilles Lock and Dam: Hydraulic Model Investigation
A 1:20-scale hydraulic model simulated a 120-ft-wide section of the spillway and stilling basin including one freely suspended 60-ft-wide by 16-ft-high submersible tainter gate. The gate lifting mechanism consisted of a cable at each end of the gate attached to load cells. The magnitude and frequency of the forces acting on the cable supporting each end of the gate were measured. Tests indicated that there was a likelihood of the cables being subjected to exciting forces occurring at a random frequency with flow (a) over and (b) under the subject gate. The magnitude of these forces was about 1 percent of the total gate weight. Discharge characteristics and coefficients and stilling basin performance with various operating scenarios were determined. Keywords: Hydraulic forces, Submersible gates, Spillway, F Vibrations. (aw)
Submersible-Type Tainter Gate for Spillway Marseilles Lock and Dam: Hydraulic Model Investigation
D. R. Cooper (author)
1989
86 pages
Report
No indication
English
Solutions to Spillway Tainter Gate Icing Problems
ASCE | 1999
|Design of Spillway Tainter Gates
NTIS | 2000
Spillway Tainter Gate Failure at Folsom Dam, California
ASCE | 1999
|Method for mounting extra-large tainter gate of hydropower station spillway
European Patent Office | 2016
|