A platform for research: civil engineering, architecture and urbanism
Time Effects on Resin-Grouted Bolt Anchorage Characteristics
The technical analysis of parameters that can influence roof and rib reinforcement is important to the operation of safe and profitable underground mines. One such parameter, studied in the U.S. Bureau of Mines investigation, is the effect of time on untensioned, resin-grouted bolt anchorage characteristics. A group of seventy-three 4-ft-long bolts with three different grout column lengths were installed in a stable coal mine roof. The bolts were then subjected to standardized pull tests at various intervals throughout a 37-month period. For each test, load-deformation data were reduced to determine axial stiffness and yield point. The magnitudes of these two anchorage characteristics at the time of installation were compared with results from subsequent pull tests to determine if anchorage capacity deteriorated. Bolts with 18-in grout columns were studied over 9 months, and no measurable loss occurred. Bolts with 48- and 24-in grout columns were studied over 37 months and also exhibited no measurable loss.
Time Effects on Resin-Grouted Bolt Anchorage Characteristics
The technical analysis of parameters that can influence roof and rib reinforcement is important to the operation of safe and profitable underground mines. One such parameter, studied in the U.S. Bureau of Mines investigation, is the effect of time on untensioned, resin-grouted bolt anchorage characteristics. A group of seventy-three 4-ft-long bolts with three different grout column lengths were installed in a stable coal mine roof. The bolts were then subjected to standardized pull tests at various intervals throughout a 37-month period. For each test, load-deformation data were reduced to determine axial stiffness and yield point. The magnitudes of these two anchorage characteristics at the time of installation were compared with results from subsequent pull tests to determine if anchorage capacity deteriorated. Bolts with 18-in grout columns were studied over 9 months, and no measurable loss occurred. Bolts with 48- and 24-in grout columns were studied over 37 months and also exhibited no measurable loss.
Time Effects on Resin-Grouted Bolt Anchorage Characteristics
W. J. Wuest (author) / R. M. Stateham (author)
1989
17 pages
Report
No indication
English
Anchorage Performance of Geopolymer-Grouted Rock Bolts
ASCE | 2022
|Anchorage of Bundled Bars Grouted in Ducts
British Library Online Contents | 2018
|Anchorage Pull Testing for Fully Grouted Roof Bolts
NTIS | 2008
|