A platform for research: civil engineering, architecture and urbanism
Structural Collapse Fire Tests: Single Story, Wood Frame Structures
A series of fire tests was conducted in Phoenix, Arizona to collect data for a project examining the feasibility of predicting structural collapse. The fire test scenario was selected as part of a training video being prepared by the Phoenix, Arizona Fire Department. Multiple fires were started in each structure to facilitate collapse; the fires were not intended to test the fire endurance of the structures. Four structures with different roof constructions were used for the fire tests. Temperatures were measured as a function of time in four locations within each structure. Furniture items were placed in the front and back of each structure to simulate living room and bedroom areas. The living room and bedroom areas of each structure were ignited simultaneously using electric matches. Peak temperatures obtained during the tests ranged from approximately 800 deg C (1500 deg F) to 1000 deg C (1800 deg F). The roof of each structure collapsed approximately 17 minutes after ignition. In addition to the full scale tests, the plywood and oriented strand board (OSB) roofing materials were tested using a cone calorimeter to characterize the fire properties of the materials.
Structural Collapse Fire Tests: Single Story, Wood Frame Structures
A series of fire tests was conducted in Phoenix, Arizona to collect data for a project examining the feasibility of predicting structural collapse. The fire test scenario was selected as part of a training video being prepared by the Phoenix, Arizona Fire Department. Multiple fires were started in each structure to facilitate collapse; the fires were not intended to test the fire endurance of the structures. Four structures with different roof constructions were used for the fire tests. Temperatures were measured as a function of time in four locations within each structure. Furniture items were placed in the front and back of each structure to simulate living room and bedroom areas. The living room and bedroom areas of each structure were ignited simultaneously using electric matches. Peak temperatures obtained during the tests ranged from approximately 800 deg C (1500 deg F) to 1000 deg C (1800 deg F). The roof of each structure collapsed approximately 17 minutes after ignition. In addition to the full scale tests, the plywood and oriented strand board (OSB) roofing materials were tested using a cone calorimeter to characterize the fire properties of the materials.
Structural Collapse Fire Tests: Single Story, Wood Frame Structures
D. W. Stroup (author) / N. P. Bryner (author) / J. Lee (author) / J. McElroy (author) / G. Roadarmel (author)
2004
90 pages
Report
No indication
English
COLLAPSE AND FIRE EXTENSION IN WOOD-FRAME CONSTRUCTION
British Library Online Contents | 2006
|Experimental Seismic Collapse Study of a Full-Scale, 4-Story, Soft-Story, Wood-Frame Building
British Library Online Contents | 2015
|Experimental Seismic Collapse Study of a Full-Scale, 4-Story, Soft-Story, Wood-Frame Building
Online Contents | 2015
|