C-Pile recommended flow -- Pressure characteristic curve and orifice pattern
Final approval of a flow-pressure characteristic curve and orifice pattern for C Pile is desired as soon as possible to allow the completion of orifice assemblies and parallit instrumentation. The presentation of a recommended flow-pressure curve and an orifice pattern has been delayed by a lack of experimental flow data on the C Pile flow system. Discussion with members of the C-431-B working committee and Pile Technology Unit personnel indicated that the use of flows higher than those recommended by the Reactor Unit, in HDC-2327, was desirable on the basis that the costs of supplying more water to C Pile than required by present outlet temperature limits will be small compared to the probable saving that can be made in reduction of corrosion and slug rupture frequency. Using this agreement as well as previous data and the assumption of low enrichment as a basis, a preliminary recommendation of a higher flow curve is presented.
C-Pile recommended flow -- Pressure characteristic curve and orifice pattern
Final approval of a flow-pressure characteristic curve and orifice pattern for C Pile is desired as soon as possible to allow the completion of orifice assemblies and parallit instrumentation. The presentation of a recommended flow-pressure curve and an orifice pattern has been delayed by a lack of experimental flow data on the C Pile flow system. Discussion with members of the C-431-B working committee and Pile Technology Unit personnel indicated that the use of flows higher than those recommended by the Reactor Unit, in HDC-2327, was desirable on the basis that the costs of supplying more water to C Pile than required by present outlet temperature limits will be small compared to the probable saving that can be made in reduction of corrosion and slug rupture frequency. Using this agreement as well as previous data and the assumption of low enrichment as a basis, a preliminary recommendation of a higher flow curve is presented.
C-Pile recommended flow -- Pressure characteristic curve and orifice pattern
H. G. Spencer (author)
1952
14 pages
Report
No indication
English
Novel pile foundation reinforcement cage orifice supporting cushion device
European Patent Office | 2024
|Recommended C Pile power level limits
NTIS | 1952
|Study on Automatic Measurement of Valve Orifice Characteristic Based on Pneumatic Flow Method