The project involved the construction of two Trombe wall systems to be attached to a residential building for mentally retarded persons. The construction and information phases of this project are briefly discussed. The thermal analysis and load calculations are attached. (ERA citation 09:007395)
The project involved the construction of two Trombe wall systems to be attached to a residential building for mentally retarded persons. The construction and information phases of this project are briefly discussed. The thermal analysis and load calculations are attached. (ERA citation 09:007395)
Trombe Wall Retrofit. Final Performance Report
A. Wilson (author)
1979
7 pages
Report
No indication
English
British Library Conference Proceedings | 1984
|Trombe wall permeable to light