A platform for research: civil engineering, architecture and urbanism
Three-Cable Median Barrier. Final Report
Oregon public interest peaked regarding crossover highway safety following three fatalities from a crossover accident in August of 1996. The Oregon Department of Transportation (ODOT) conducted a review of possible barrier solutions for the interstate highway median near Salem, Oregon. The weak-post three-cable median barrier system was selected. Unfortunately, there is not much information concerning the maintenance and repair costs of the cable barrier system. This study evaluates the effectiveness of the three-cable barrier in preventing crossover accidents on Interstate 5 (I-5), Oregon Highway Number 1, and evaluates the maintenance and repair costs in order to make recommendations for future installations. Based on the results of the study, the cable median barrier system proved to be cost-effective when compared to the concrete median barrier system and the system performed well, decreasing crossover accidents in the area. The cable median barrier system works well in medians with a minimum of 7 m width, where it is used to prevent the infrequent potentially catastrophic cross-median accidents.
Three-Cable Median Barrier. Final Report
Oregon public interest peaked regarding crossover highway safety following three fatalities from a crossover accident in August of 1996. The Oregon Department of Transportation (ODOT) conducted a review of possible barrier solutions for the interstate highway median near Salem, Oregon. The weak-post three-cable median barrier system was selected. Unfortunately, there is not much information concerning the maintenance and repair costs of the cable barrier system. This study evaluates the effectiveness of the three-cable barrier in preventing crossover accidents on Interstate 5 (I-5), Oregon Highway Number 1, and evaluates the maintenance and repair costs in order to make recommendations for future installations. Based on the results of the study, the cable median barrier system proved to be cost-effective when compared to the concrete median barrier system and the system performed well, decreasing crossover accidents in the area. The cable median barrier system works well in medians with a minimum of 7 m width, where it is used to prevent the infrequent potentially catastrophic cross-median accidents.
Three-Cable Median Barrier. Final Report
B. Sposito (author) / S. Johnston (author)
1998
50 pages
Report
No indication
English
Transportation Safety , Road Transportation , Transportation , Transportation & Traffic Planning , Median barriers , Accident prevention , Median crossover collisions , Effectiveness , Barriers , Maintenance costs , Repair costs , Performance evaluation , Cost effectiveness , Oregon , Three-cable barrier system
Washington State Cable Median Barrier
British Library Online Contents | 2001
|Washington State Cable Median Barrier
British Library Conference Proceedings | 2001
|Guidelines for Implementation of Cable Median Barrier
British Library Online Contents | 2009
|Three-Strand Cable Median Barrier in North Carolina: In-Service Evaluation
British Library Online Contents | 2001
|Three-Strand Cable Median Barrier in North Carolina: In-Service Evaluation
British Library Conference Proceedings | 2001
|