Wear tests were performed using nine commercial low inflammability hydraulic fluids on a Tribolub machine following the procedure normally used with mineral hydraulic oils. The results show that aqueous fluids performance is close to that of mineral oils. The temperature and viscosity effects on the protection properties are also detailed.
Wear tests were performed using nine commercial low inflammability hydraulic fluids on a Tribolub machine following the procedure normally used with mineral hydraulic oils. The results show that aqueous fluids performance is close to that of mineral oils. The temperature and viscosity effects on the protection properties are also detailed.
Evaluation du Pouvoir de Protection Contre l'Usure des Fluides Difficilement Inflammables du Type Hfc (Solutions de Polyglycol) (Evaluation of the Erosion Protection of Low Inflammability Liquids of the Hfc Type (Polyglycol Solutions))