Wind response of a tall building with full-scale observations. Phase 2
A 22-story hotel is the subject of a full-scale experimental study conducted as the second phase of a project addressing the wind-induced response of tall buildings. The first phase of this study investigated a 16-story office building. The observations of wind loading and building response obtained at the hotel site reflect similar behavior as was observed at the office building. Consequently, the second phase serves to reinforce and generalize the findings of the phase one study. The results illustrate the significance of wind-induced response for buildings of intermediate height. Based on estimated thresholds of human perceptibility combined with predictions of maximum building response from a theoretical analysis, clearly perceptible wind-induced motion is expected to occur annually at the hotel. Yet, motion will not be sufficient intensity to be unpleasant. A similar analysis suggests that building response will also produce some non-structural damage on an annual basis. 3 refs., 5 figs., 2 tabs.
Wind response of a tall building with full-scale observations. Phase 2
A 22-story hotel is the subject of a full-scale experimental study conducted as the second phase of a project addressing the wind-induced response of tall buildings. The first phase of this study investigated a 16-story office building. The observations of wind loading and building response obtained at the hotel site reflect similar behavior as was observed at the office building. Consequently, the second phase serves to reinforce and generalize the findings of the phase one study. The results illustrate the significance of wind-induced response for buildings of intermediate height. Based on estimated thresholds of human perceptibility combined with predictions of maximum building response from a theoretical analysis, clearly perceptible wind-induced motion is expected to occur annually at the hotel. Yet, motion will not be sufficient intensity to be unpleasant. A similar analysis suggests that building response will also produce some non-structural damage on an annual basis. 3 refs., 5 figs., 2 tabs.
Wind response of a tall building with full-scale observations. Phase 2
R. S. Mills (author)
1991
27 pages
Report
No indication
English
Structural Analyses , Commercial Buildings , Wind Loads , Damage , Motion , Storms , Stresses , Wind , EDB/320100
Full-Scale Validation of Dynamic Wind Load on a Super-Tall Building under Strong Wind
British Library Online Contents | 2012
|Full-scale performance evaluation of tall buildings under wind
Online Contents | 2012
|