A platform for research: civil engineering, architecture and urbanism
Flat Slabs in Post-Tensioned Concrete with Particular Regard to the Use of Unbonded Tendons - Design Recommendations
This report is intended to assist engineers in the development of post-tensioned concrete flat slab structures. It incorporates, as far as possible, the limit state design principles of the British Code of Practice, CP 110 and other recent technical publications. Information is given on the materials used and on the design for different limit states of the slab, types of loadings, analysis of the flat slabs and slab sections, and on the prestressing tendons.
Flat Slabs in Post-Tensioned Concrete with Particular Regard to the Use of Unbonded Tendons - Design Recommendations
This report is intended to assist engineers in the development of post-tensioned concrete flat slab structures. It incorporates, as far as possible, the limit state design principles of the British Code of Practice, CP 110 and other recent technical publications. Information is given on the materials used and on the design for different limit states of the slab, types of loadings, analysis of the flat slabs and slab sections, and on the prestressing tendons.
Flat Slabs in Post-Tensioned Concrete with Particular Regard to the Use of Unbonded Tendons - Design Recommendations
1979
20 pages
Report
No indication
English
High-Strength Concrete Slabs Post-Tensioned with Unbonded Tendons
British Library Conference Proceedings | 1996
|Structural fire performance of post-tensioned concrete slabs with unbonded tendons
BASE | 2014
|Nonlinear behaviour of continuous slabs post-tensioned with unbonded tendons
British Library Conference Proceedings | 1994
|