A platform for research: civil engineering, architecture and urbanism
Mechanical Response of Titanium Aluminide (TiAl3)
Compression tests have been performed on TiAl3 at strain rates from 0.00003-500/s. All tests were done at room temperature and were designed to investigate the stress-strain response of the material. In addition to these tests elastic constants were calculated from ultrasound measurements. The results were used to find an approximate failure stress for the material.
Mechanical Response of Titanium Aluminide (TiAl3)
Compression tests have been performed on TiAl3 at strain rates from 0.00003-500/s. All tests were done at room temperature and were designed to investigate the stress-strain response of the material. In addition to these tests elastic constants were calculated from ultrasound measurements. The results were used to find an approximate failure stress for the material.
Mechanical Response of Titanium Aluminide (TiAl3)
A. Dwivedi (author) / J. Bradley (author)
2010
23 pages
Report
No indication
English
Basic & Synthetic Chemistry , Structural Mechanics , Failure(Mechanics) , Titanium aluminide , Aluminides , Compression , Mechanical properties , Room temperature , Ultrasonics , Response , Constants , Measurement , Stress strain relations , Stresses , Test and evaluation , Elastic properties , Solidica , Ultrasonic consolidation
Mechanical response of titanium tri-aluminide intermetallic alloy
British Library Online Contents | 2017
|XD Titanium Aluminide Composites
British Library Online Contents | 1995
|Reactive hot pressing and mechanical properties of TiAl3/Ti3AlC2/Al2O3 in situ composite
British Library Online Contents | 2013
|Microstructure evolution and oxidation behaviour of Tif/TiAl3 composites
British Library Online Contents | 2011
|Microstructure and mechanical properties of titanium aluminide compositions containing Fe
British Library Online Contents | 2013
|