In a program of evaluation of various housing systems proposed under Operation BREAKTHROUGH, a fire endurance test was performed at the National Bureau of Standards on a roof/ceiling assembly consisting of a paper honeycomb structural core surfaced both sides with glass-fabric impregnated with polyester resin and outer layers of gypsum board. The test method was generally in accordance with the requirements of ASTM E 119 for loadbearing roof assemblies. The applied load was 15.9 psf and the test results are valid only for roof/ceilings of similar construction loaded at or below the stress level developed by this loading. Under a loading equivalent to the application of 20 psf on a 12 ft. span, failure time by flame-through was noted.
In a program of evaluation of various housing systems proposed under Operation BREAKTHROUGH, a fire endurance test was performed at the National Bureau of Standards on a roof/ceiling assembly consisting of a paper honeycomb structural core surfaced both sides with glass-fabric impregnated with polyester resin and outer layers of gypsum board. The test method was generally in accordance with the requirements of ASTM E 119 for loadbearing roof assemblies. The applied load was 15.9 psf and the test results are valid only for roof/ceilings of similar construction loaded at or below the stress level developed by this loading. Under a loading equivalent to the application of 20 psf on a 12 ft. span, failure time by flame-through was noted.
Fire Endurance Test of a Roof/Ceiling Construction of Paper Honeycomb and Gypsum Board
B. C. Son (author)
1973
21 pages
Report
No indication
English
Materials Sciences , Building Standards & Codes , Honeycomb structures , Fire tests , Roofs , Ceilings(Architecture) , Residential buildings , Glass coatings , Polyester fibers , Gypsum , Panels , Fire safety , Honeycomb cores , Papers , Evaluation , Flames , Failure , Time , Loads(Forces) , Fire endurance tests , Breakthrough operation , Flamethrough , Roof ceiling assemblies , Glass cloth