A platform for research: civil engineering, architecture and urbanism
Barrel Vault 96 Meters Long Check Tested Against Design
Check tests have been made on a prefabricated barrel vault which was developed and used in the roofs of two bus garages in Leningrad. The experimental results were used to evaluate the structure. This article evaluates the approximation method of designing a vault as a flat double-hinged arch with an elastic tie beam, and the effect of the three-dimensional working of the vault on the distribution of forces.
Barrel Vault 96 Meters Long Check Tested Against Design
Check tests have been made on a prefabricated barrel vault which was developed and used in the roofs of two bus garages in Leningrad. The experimental results were used to evaluate the structure. This article evaluates the approximation method of designing a vault as a flat double-hinged arch with an elastic tie beam, and the effect of the three-dimensional working of the vault on the distribution of forces.
Barrel Vault 96 Meters Long Check Tested Against Design
Y. V. Chinenkov (author)
1974
13 pages