A platform for research: civil engineering, architecture and urbanism
Application of Fiber Reinforced Plastic Rods as Prestressing Tendons in Concrete Structures
The study is concerned with the possibility of utilizing fiber reinforced plastic rods as prestressing tendons, in place of traditional steel tendons, in elements of prestressed concrete bridges exposed to corrosive environments. A survey was made of available information on the behavior characteristics of fiber reinforced plastic tension elements, and in particular those of glass fiber reinforced (GFR) tensions elements. Also, an analytical study was made of the flexural behavior of concrete elements prestressed by GFR tendons. Based on the analytical study and on the survey of available information, an assessment is made of the impact on the design of prestressed concrete members if GFR tendons are used. Some preliminary design recommendations are made, together with proposals for research needed before GFR prestressing tendons should be used in practice. Four GFR tendons with Con-Tech Systems anchorages were tested, the primary variable being the embedded length of the GFR rods in the anchorages. All the tendons failed by the rods pulling out of the anchorages. For embedded lengths of 385 (15.2 in) or greater, the failure loads were 90% of the advertised tendon strength of 220 ksi, or about 100% of the guaranteed tensile strength of 197 ksi (60 kN/rod).
Application of Fiber Reinforced Plastic Rods as Prestressing Tendons in Concrete Structures
The study is concerned with the possibility of utilizing fiber reinforced plastic rods as prestressing tendons, in place of traditional steel tendons, in elements of prestressed concrete bridges exposed to corrosive environments. A survey was made of available information on the behavior characteristics of fiber reinforced plastic tension elements, and in particular those of glass fiber reinforced (GFR) tensions elements. Also, an analytical study was made of the flexural behavior of concrete elements prestressed by GFR tendons. Based on the analytical study and on the survey of available information, an assessment is made of the impact on the design of prestressed concrete members if GFR tendons are used. Some preliminary design recommendations are made, together with proposals for research needed before GFR prestressing tendons should be used in practice. Four GFR tendons with Con-Tech Systems anchorages were tested, the primary variable being the embedded length of the GFR rods in the anchorages. All the tendons failed by the rods pulling out of the anchorages. For embedded lengths of 385 (15.2 in) or greater, the failure loads were 90% of the advertised tendon strength of 220 ksi, or about 100% of the guaranteed tensile strength of 197 ksi (60 kN/rod).
Application of Fiber Reinforced Plastic Rods as Prestressing Tendons in Concrete Structures
A. H. Mattock (author) / K. Babaei (author)
1989
58 pages
Report
No indication
English
Highway Engineering , Structural Analyses , Construction Materials, Components, & Equipment , Bridges(Structures) , Prestressed concrete , Reinforced plastics , Fiber laminates , Corrosion prevention , Glass fibers , Tensile strength , Flexural strength , Mechanical tests , Structural design , Anchors(Structures)
Properties of Fiber Reinforced Plastic Rods for Prestressing Tendons
British Library Conference Proceedings | 1993
|Prestressing concrete structures with FRP tendons
TIBKAT | 2004
|Grouted anchorages for aramid fibre reinforced plastic prestressing tendons
British Library Online Contents | 1993
|Grouted anchorages for aramid fibre reinforced plastic prestressing tendons
Online Contents | 1993
|Prestressing with Carbon Fiber Reinforced Polymers (CFRP) Tendons
British Library Conference Proceedings | 2003
|